Waterpik Technologies LD User Manual

Page 13

Advertising
background image

Model LG & LD Pool and Spa Heater

Page 11

1.

Remove heater door.

2.

If there is a vent cap or drafthood (indoor) on top

of the heater, remove it.

3.

Remove all 8 hex-head screws fastening the top

and lift the top assembly straight up (see Figure

12).

4.

Remove rainshield assembly and set it aside.

5.

Remove screws that fasten the gap closures to the

jacket and put them aside. Remove gap closures.

6.

Remove the screws securing the two flue collec-

tor hold down clamps and remove the clamps (see

Figure 13). Remove flue collector.

7.

Remove the three rubber jacket/plug grommets

and drain plugs (see Figure 12). One is located

under the water connections on the right side. The

other two are on the left side toward the front of

the heater.

8.

Tag and disconnect the white wire on the pressure

switch (PS) and the white wire on the Fireman's

switch terminal (see Figure 6 or 7) which leads to

the high limit switch.

9.

Remove plastic tie wraps and pull the white wires

out of the front compartment through the vesti-

bule cover and coil them on the heat exchanger.

10. Unscrew the brass compression fitting securing

the pressure switch to the inlet/outlet header.

Remove tube from header and gently bend it out

of the way.

11. Loosen the screw securing the temperature sensing

bulb retainer bracket. Slide the retainer bracket off

the bulb flange and remove the bulb from the header

Figure 13. Flue collector hold-down brackets.

HOLD DOWN
CLAMP

IN/OUT HEADER

BRACKET

Figure 15. Vestibule covers.

FRONT

PLASTIC BUSHING

LEFT

VESTIBULE

COVER

RIGHT

VESTIBULE

COVER

(U.S. MODELS

ONLY)

Figure 14. Temperature sensing bulb.

(see Figure 14). Pull pressure switch tube through

the hole in the vestibule cover and into the vesti-

bule (controls compartment), then pull thermostat

bulb assembly through same hole (see Figure 15).

12. When removing the heat exchanger from the

heater, the end baffles of the heat exchanger must

be removed. There are two baffles covering part

of the front and rear tubes of the heat exchanger.

Each baffle is held in place by two screws which

mount to the top of the combustion chamber wall.

Remove the screws and the baffles before at-

tempting to lift the heat exchanger out of the

heater (see Figure 16).

Caution

It may be necessary to have help lifting the

heat exchanger out and replacing it.

Advertising