3H. Periodic Inspection

3H-1. Owner Inspection

Waterpik Laars designs and constructs the Laars

Lite 2 heater to provide long performance life when

installed and operated properly under normal condi-

tions. The following basic guidelines are suggested for

your inspection:
1.

Keep the top and surrounding area of the heater

clear of all debris.

2.

Keep the heater area clean and free of all com-

bustible materials, flammable liquids and vapors,

as well as sanitization chemicals.

3.

Do not use the heater if any part has been under

water. Immediately call a qualified professional

technician to inspect the heater and replace any

part of the control system which has been sub-

merged.
N'utilisez pas cet appareil s'il a été plongé dans

l'eau, même partiellement. Faites inspecter

l'appareil par un technicien qualifié et remplacez

toute partie du système de contrôle et toute

commande qui ont été plongés dans l'eau.

4.

If the heater is equipped with a pressure relief

valve, check for corrosion in and around the

valve. With the filter pump on, lift the release

lever on the top of the valve to make sure that

water runs freely through it. If corrosion is found,

replace the pressure relief valve. When replacing

the valve, be sure that the pump is off. Install the

valve so that the discharge is directed away from

any area the may be damaged by water.

5.

Be sure all combustion air and ventilation open-

ings are not blocked.

3H-2. Professional Inspection

In addition, annual inspections by a qualified

professional technician are recommended to keep the

heater operating safely and efficiently through the years.

The following basic checks should be performed.

1. Check for loose or broken wires and terminal

connections.

2. Verify pressure switch operation by cycling

the spa pump on and off a few times. The

heater should go off immediately after the

pump stops.

3. Inspect the electrical controls, specifically the

following:
a. High limit controls.

b. Pressure switch.

c. Temperature control.

d. Automatic gas valve.

4. Inspect the venting system for blockage,

leakage, and corrosion.

5. Check for spider webs in the pilot and main

burner orifices - especially at Spring start-up.

6. Conduct a normal operating cycle and observe

that the sequence proceeds as intended.

7. Inspect the external surfaces of the heat

exchanger tubes for black carbon soot buildup

by placing a mirror between and under the

burners when the heater is firing. Remove any

soot that has collected on the tubes, and

correct the cause.

NOTE: After installation and first start-up,

check the heat exchanger for black carbon soot

buildup after the following periods of operation: 24

hours, 7 days, 30 days, 90 days, and once every 6

months thereafter.

Proper flames appear:

a. Blue in color.

b. 1 to 4 inches (25 to 102mm) high above

burner surface.

SECTION 4.

Parts List for Laars Lite 2 Heater

4A. General Information

To purchase parts or obtain a comprehensive

maintenance manual for the Laars Lite 2 heater,

contact your nearest Waterpik Laars dealer or

distributor. If they cannot supply you with what you

need, contact the Customer Service Manager,

Waterpik Laars, 21 Pimentel Ct, Novato, California,

94949, Telephone (415) 382-8220 extension 245.

4B. Parts List

The following three pages contain a parts list,

general exploded view and detailed exploded views to

aid in parts identification. Please refer to these pages

when ordering parts for your Laars Lite 2 pool heater.

WARNING

Improper installation or maintenance can

cause nausea or asphyxiation from carbon

monoxide in flue gases which could result in

severe injury, or death.