Locate the heater in an open, unroofed area. Do

not install the heater under a deck. Do not locate the

heater below or adjacent to any doors, glass openings,

louvers, grills, etc., which connect in any way with an

inhabited area of a building, even though the access

might be through another structure (e.g., a garage or

utility room. In the United States there must be a

minimum of 4 feet (1.22 m) horizontally or vertically

between the heater and any door, glass opening, or

gravity inlet to a building. In Canada this distance

must be at least 10 feet (3.0 m) (see Figure 3).

WARNING

United States

Do not install the heater with the top of the

vent assembly within 4 feet (1.22 m) of any

opening into a building.

Canada

Do not install the heater with the top of the

vent assembly within 10 feet (3.05 m) of any

opening into a building.

If the heater is installed under an overhang, there

must be a minimum clearance of 5 feet (1.5 m) above

the top of the heater and the structure should not

overhang the heater more than 12 inches (0.30 m). The

area under the overhang must be open on three sides.

This prevents combustion gases from being diverted

into living areas through doors, windows, or gravity

inlets.

If the heater is installed close to a structure,

protect it from rain water runoff with rain gutters on

the roof or other measures. Do not locate the heater

near sprinkler systems that could spray water on it.

Avoid locations where wind deflection off nearby

structures might cause downdraft conditions. Where

downdraft conditions exist, locate the heater at least 3

Figure 4. Non-Combustible Platform.

Notes:

1. Blocks must provide solid base and be braced so they

cannot slip out of place.

2. Air openings in blocks must be arranged to provide

unrestricted opening through entire width or length of

base.

Figure 3. Outdoor Heater Installation.

2C-2. Outdoor Installation

Laars Lite 2 heaters can be installed in the low-

profile, grate top configuration (U.S.A. only) as

received from the factory, or with an optional high

wind vent cap/stack. Canadian units require a factory

approved vent cap.

feet (0.91 m) from vertical surfaces (e.g., nearby

buildings and walls). The addition of a vent cap may

be necessary.

2C-3. Flooring - Typical Installation

Do not install the heater directly on a combus-

tible wood or carpet floor without placing a noncom-

bustible platform between the floor and the heater. In

the United States, the National Fuel Gas Code allows a

heater to be placed on a combustible surface when

there is a platform under the heater made of hollow

masonry no less than 4 inches (102 millimeters [mm])

thick, covered with sheet metal at least 24 gauge thick

and extending beyond the full width and depth of the

heater by at least 6 inches (76.2 mm) in all directions.

The masonry must be laid with ends unsealed, and

joints matched to provide free circulation of air from

side to side through the masonry (see Figure 4). If the

heater is installed in a carpeted alcove, the entire floor

of the alcove must be covered by a noncombustible

panel. You can obtain a noncombustible base from

Waterpik Laars, see the Parts List (Sec. 4) of this

manual.

2C-4. Indoor and Outdoor Shelter

Installations

All indoor installations and outdoor shelter

installations (Canada) require the addition of a factory

approved drafthood. The drafthood must be installed