Model LG & LD Pool and Spa Heater

Page 1

SECTION 1.

General Information

1A. Introduction

This manual provides installation and operation

instructions for the Laars Lite 2, Model LG and LD

pool and spa heaters. Read these installation and

operation instructions completely before proceeding

Figure 1. General Configuration.

with the installation. Consult the Waterpik Laars

factory, or local factory representative, with any

questions regarding this equipment. Experience has

shown that most operating problems are caused by

improper installation.

The Laars Lite 2 heater is design certified by

International Approval Services (formerly American

Gas Association and Canadian Gas Association) as

complying with the latest edition of the Standard for

Notes:

1. In Canada, derate BTU/Hr input and output 10 percent for altitudes of 2,000 to 4,500 feet (609 to 1372 m) above sea

level. No derating necessary up to altitude of 2,000 feet (609 m). In United States derate input 4 percent for each 1,000

feet (305 m) above sea level, starting at 2,000 feet (609m).

2. The Laars Lite 2 is constructed for 75 psi working pressure.

3. Ratings shown are for both natural and propane gas.

Venting Dimensions

Model

Heater

U.S. Indoor or

Firing Rate / Hr.

Size

Width

Vent

U.S. Outdoor

CAN Outdoor

(1,000's)

Diameter

Dim "H"

Shelter Dim "H"

in

(cm)

in

(cm)

in

(cm)

in

(cm)

BTU

(kcal)

125

15

(38)

5

(12.7)

9 1/8

(23)

16 1/4

(41.3)

125

(31.5)

175

18

(45.7)

6

(15.2)

9 3/4

(24)

24 1/8

(61.3)

175

(44.1)

250

22 1/2

(57.2)

7

(17.8)

10

(26)

25 1/4

(64.1)

250

(63)

325

26 3/4

(67.9)

8

(20.3)

10 5/8

(27)

26 1/2

(67.3)

325

(81.9)

400

31 3/4

(80.6)

9

(22.9)

13 1/4

(34)

27 1/2

(69.9)

400

(101)

(920 cm)