2

1.

POWER SWITCH

FRYER position turns ON the FRYER and energizes the UPPER

(FRYER-OFF-FILTER)

CONTROL PANEL; and, turns OFF the FILTER PUMP.
Burner circuits are energized and regulate to the programmed

temperature.

OFF position turns OFF the FRYER .
FILTER position energizes the FILTER PUMP.

2.

TIME KEY

Used to check and set menu times.

3.

TEMP KEY

Used to check and set menu temperatures.

4.

READOUT

LED display of various data and functions.

5.

UP ARROW KEY

Used to raise FRY BASKET and raise program settings .

6.

DOWN ARROW KEY

Used to lower FRY BASKET and lower program settings .

7.

MENU KEYS

Used to begin a menu time/temp cycle.
Keys 1 thru 6 are programmable for time and temperature;
Key 7 is available for individually set time/temp cook cycles

8.

FUNCTION KEYS

Used to perform the functions of PAUSE, CLEAN, STANDBY,
BASKET (raise/lower) and FILTER (warning/acknowledge)

9.

HI-LIMIT THERMOSTAT

Provides over-temperature protection by de-energizing the
GAS VALVES if the oil temperature exceeds the factory-set
limit. RESET must be performed manually. Allow the oil to
cool below 350ºF (177ºC), then firmly press the red button on
the LOWER CONTROL PANEL until it “clicks”.

WFGA-60FS w/SOLID STATE CONTROLLER

FEATURES and OPERATING CONTROLS

FRONT VIEW

9

BACK VIEW

LOWER CONTROL PANEL

RESET

HI-LIMIT

UPPER CONTROL PANEL

8

10

3

4

5

2

6

7

1

2

3

4

5

6

7

TIME

TEMP

HEAT READY MANUAL

MANUAL

PAUSE CLEAN STANDBY BASKET FILTER

FRYER

OFF

FILTER

1

11

12

13

18

19

14

20

21

15

16

17

22

23

Advertising