York PREDATOR R-410A User Manual

Page 58

Advertising
background image

528150-YTG-C-1109

58

Johnson Controls Unitary Products

115°F

125°F

2500

77

113.0

11.0

47.0

40.7

30.0

-

-

-

101.1

12.1

44.1

37.0

26.4

-

-

-

72

104.5

11.0

69.2

58.5

47.8

37.1

-

-

93.6

12.1

65.1

54.5

43.9

33.3

-

-

67

96.0

11.0

91.4

76.3

65.6

55.0

44.3

-

86.1

12.1

86.1

72.0

61.4

50.8

40.2

-

62

89.7

11.0

89.7

89.7

79.8

69.1

58.4

47.7

81.3

12.1

81.3

81.3

74.1

63.0

52.3

41.7

3000

77

119.6

11.1

58.6

46.1

33.6

-

-

-

108.1

12.1

57.2

42.5

30.0

-

-

-

72

110.6

11.1

78.6

66.1

53.5

41.0

-

-

100.1

12.2

74.7

62.2

49.8

37.3

-

-

67

101.6

11.1

98.5

86.0

73.5

61.0

48.5

-

92.1

12.2

92.1

82.0

69.5

57.1

44.6

-

62

94.9

11.0

94.9

94.9

89.3

76.8

64.3

51.8

87.0

12.2

87.0

87.0

83.3

70.9

58.4

46.0

57

94.9

11.0

94.9

94.9

85.5

73.0

60.5

47.9

86.7

12.0

86.7

86.7

77.8

65.3

52.9

40.4

3500

77

126.1

11.2

70.2

51.5

37.2

-

-

-

115.1

12.2

70.3

47.9

33.6

-

-

-

72

116.6

11.2

87.9

73.6

59.3

44.9

-

-

106.6

12.3

84.2

69.9

55.6

41.3

-

-

67

107.2

11.2

105.6

95.7

81.4

67.0

52.7

-

98.1

12.3

98.1

92.0

77.7

63.4

49.1

-

62

100.1

11.1

100.1

100.1

98.9

84.6

70.2

55.9

92.6

12.3

92.6

92.6

92.6

78.8

64.6

50.3

57

100.1

11.0

100.1

100.1

94.6

80.3

66.0

51.6

92.3

12.1

92.3

92.3

87.0

72.7

58.4

44.1

4000

77

132.7

11.3

81.8

56.9

40.8

-

-

-

122.2

12.3

83.4

53.3

37.1

-

-

-

72

122.7

11.3

97.3

81.1

65.0

48.8

-

-

113.1

12.4

93.7

77.6

61.5

45.3

-

-

67

112.7

11.3

112.7

105.4

89.2

73.1

56.9

-

104.1

12.4

104.1

102.0

85.8

69.7

53.6

-

62

105.3

11.2

105.3

105.3

108.4

92.3

76.1

60.0

98.2

12.4

98.2

98.2

98.2

86.8

70.7

54.5

57

105.3

11.1

105.3

105.3

103.7

87.6

71.5

55.3

98.0

12.2

98.0

98.0

96.2

80.0

63.9

47.8

4500

72

123.4

11.2

104.9

87.3

69.6

52.0

-

-

113.1

12.3

100.8

83.3

65.8

48.3

-

-

67

113.3

11.2

113.3

109.7

95.6

78.0

60.4

-

104.1

12.3

104.1

104.0

91.9

74.4

56.9

-

62

105.9

11.2

105.9

105.9

107.5

89.8

72.2

54.6

98.2

12.3

98.2

98.2

98.2

83.1

65.6

48.1

57

105.9

11.1

105.9

105.9

105.1

87.5

69.9

52.2

98.0

12.2

98.0

98.0

97.1

79.6

62.1

44.6

5000

72

124.0

11.2

112.5

93.4

74.3

55.2

-

-

113.1

12.3

107.8

89.0

70.1

51.3

-

-

67

113.9

11.2

113.9

113.9

102.0

82.9

63.8

-

104.1

12.3

104.1

104.1

97.9

79.1

60.3

-

62

106.5

11.2

106.5

106.5

106.5

87.4

68.3

49.2

98.2

12.3

98.2

98.2

98.2

79.4

60.6

41.7

57

106.4

11.1

106.4

106.4

106.4

87.3

68.3

49.2

98.0

12.1

98.0

98.0

98.0

79.1

60.3

41.5

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower

Performance Table for the kW of the supply air blower motor.

2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

ZJ120 (10 Ton) (Continued)

Air on

Evaporator Coil

Temperature of Air on Condenser Coil

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

CFM

WB
(°F)

Return Dry Bulb (°F)

Return Dry Bulb (°F)

90

85

80

75

70

65

90

85

80

75

70

65