ZH078 (6.5 Ton) Bottom Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Field Supplied Drive

Standard 1.5 HP & Drive

Hi Static 2 HP & Drive

1800

775

0.31

850

0.53

924

0.72

998

0.89

1072

1.05

1147

1.20

1224

1.35

1303

1.51

1384

1.69

1469

1.89

2000

803

0.45

878

0.67

952

0.86

1026

1.03

1100

1.19

1175

1.34

1252

1.49

1331

1.65

1412

1.83

1497

2.03

2200

838

0.60

913

0.82

986

1.01

1060

1.19

1134

1.34

1210

1.49

1286

1.65

1365

1.81

1447

1.98

1532

2.18

2400

878

0.78

953

1.00

1027

1.19

1100

1.36

1174

1.52

1250

1.67

1327

1.82

1405

1.98

1487

2.16

-

-

2600

923

0.98

997

1.20

1071

1.39

1145

1.56

1219

1.72

1294

1.87

1371

2.02

1450

2.18

-

-

-

-

2800

971

1.20

1046

1.42

1119

1.61

1193

1.78

1267

1.94

1343

2.09

1419

2.24

-

-

-

-

-

-

3000

1023

1.44

1097

1.66

1171

1.85

1245

2.03

1319

2.18

-

-

-

-

-

-

-

-

-

-

3200

1077

1.71

1151

1.93

1225

2.12

1299

2.29

-

-

-

-

-

-

-

-

-

-

-

-

3400

1133

1.99

1208

2.21

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

2 HP & Field Supplied Drive

ZH090 (7.5 Ton) Bottom Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Field Supplied Drive

Standard 1.5 HP & Drive

Hi Static 3 HP & Drive

2000

803

0.45

878

0.67

952

0.86

1026

1.03

1100

1.19

1175

1.34

1252

1.49

1331

1.65

1412

1.83

1497

2.03

2200

838

0.60

913

0.82

986

1.01

1060

1.19

1134

1.34

1210

1.49

1286

1.65

1365

1.81

1447

1.98

1532

2.18

2400

878

0.78

953

1.00

1027

1.19

1100

1.36

1174

1.52

1250

1.67

1327

1.82

1405

1.98

1487

2.16

1572

2.36

2600

923

0.98

997

1.20

1071

1.39

1145

1.56

1219

1.72

1294

1.87

1371

2.02

1450

2.18

1532

2.36

1617

2.56

2800

971

1.20

1046

1.42

1119

1.61

1193

1.78

1267

1.94

1343

2.09

1419

2.24

1498

2.40

1580

2.58

1665

2.78

3000

1023

1.44

1097

1.66

1171

1.85

1245

2.03

1319

2.18

1394

2.33

1471

2.49

1550

2.65

1632

2.82

1717

3.02

3200

1077

1.71

1151

1.93

1225

2.12

1299

2.29

1373

2.45

1448

2.60

1525

2.75

1604

2.91

1686

3.09

1771

3.29

3400

1133

1.99

1208

2.21

1282

2.41

1356

2.58

1430

2.73

1505

2.88

1582

3.04

1661

3.20

1742

3.37

-

-

3600

1192

2.30

1267

2.52

1341

2.71

1414

2.88

1489

3.04

1564

3.19

1641

3.34

-

-

-

-

-

-

3800

1253

2.63

1327

2.85

1401

3.04

1475

3.21

1549

3.37

-

-

-

-

-

-

-

-

-

-

3 HP & Field Supplied Drive

ZH102 (8.5 Ton) Bottom Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 2” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.
4. Field Supplied Drive.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

FS

4

Standard 2 HP & Drive

Hi Static 3 HP & Drive

2600

674

0.71

731

0.88

786

1.05

838

1.24

887

1.42

933

1.59

974

1.74

1010

1.87

1040

1.97

1064

2.03

2800

689

0.86

746

1.02

801

1.20

854

1.38

903

1.56

948

1.73

989

1.88

1025

2.01

1056

2.11

1080

2.17

3000

707

1.01

764

1.17

819

1.35

872

1.53

921

1.71

966

1.88

1007

2.03

1043

2.16

1074

2.26

1098

2.32

3200

728

1.17

785

1.33

840

1.51

892

1.69

941

1.87

987

2.04

1028

2.20

1064

2.33

1094

2.42

1118

2.48

3400

751

1.34

808

1.51

863

1.68

915

1.87

964

2.05

1010

2.22

1051

2.37

1087

2.50

1117

2.60

1141

2.66

3600

776

1.53

833

1.70

888

1.87

941

2.06

990

2.24

1035

2.41

1076

2.56

1112

2.69

1142

2.79

1167

2.85

3800

804

1.74

861

1.90

916

2.08

969

2.26

1018

2.44

1063

2.61

1104

2.77

1140

2.90

1170

2.99

-

-

4000

835

1.97

892

2.13

947

2.31

999

2.49

1048

2.67

1094

2.84

1135

2.99

-

-

-

-

-

-

4200

867

2.21

924

2.37

979

2.55

1032

2.73

1081

2.91

1127

3.08

-

-

-

-

-

-

-

-

3 HP & Field Supplied Drive

Advertising