York PREDATOR R-410A User Manual

Page 99

Advertising
background image

528150-YTG-C-1109

Johnson Controls Unitary Products

99

120

(10)

208

16

110

24.9

3.5

9.6

5.5

0.0

None

-

-

-

52.6

58.1

60

70

E18

13.5

2

37.5

58.8

65.7

60

70

E24

18

2

50.0

74.5

81.3

80

90

E36

25.5

2

70.8

100.5

107.4

110

110

E54

40.6

2

112.7

152.9

159.7

175

175

230

16

110

24.9

3.5

9.6

5.5

0.0

None

-

-

-

52.6

58.1

60

70

E18

18

2

45.2

66.1

73

70

80

E24

24

2

60.2

84.2

91

90

100

E36

34

2

85.3

114.2

121.1

125

125

E54

54

2

135.6

141.9

148.8

175

175

460

7.8

52

12.1

1.6

4.8

2.2

0.0

None

-

-

-

25.6

27.8

30

35

E18

18

2

22.6

33.1

35.8

35

40

E24

24

2

30.1

42.1

44.8

45

45

E36

34

2

42.7

57.1

59.9

60

60

E54

54

2

67.8

71

73.7

80

80

575

5.7

38.9

8.9

1.3

3.9

1.8

0.0

None

-

-

-

19.3

21.1

25

25

E18

18

2

18.1

26.5

28.8

30

30

E24

24

2

24.1

33.7

36

35

40

E36

34

2

34.1

45.8

48

50

50

E54

54

2

54.2

56.8

59.1

70

70

150

(12.5)

208

23.1

160

36

1.5

15.2

5.5

0.0

None

-

-

-

73.2

78.7

90

100

E18

13.5

2

37.5

73.2

78.7

90

100

E24

18

2

50.0

81.5

88.3

90

100

E36

25.5

2

70.8

107.5

114.4

110

125

E54

40.6

2

112.7

159.9

166.7

175

175

230

23.1

160

36

1.5

15.2

5.5

0.0

None

-

-

-

73.2

78.7

90

100

E18

18

2

45.2

73.2

80

90

100

E24

24

2

60.2

91.2

98

100

100

E36

34

2

85.3

121.2

128.1

125

150

E54

54

2

135.6

148.9

155.8

175

175

460

12.2

87

19

0.8

7.6

2.2

0.0

None

-

-

-

38.3

40.5

50

50

E18

18

2

22.6

38.3

40.5

50

50

E24

24

2

30.1

45.6

48.3

50

50

E36

34

2

42.7

60.6

63.4

70

70

E54

54

2

67.8

74.5

77.2

90

90

575

8.7

62

13.5

0.6

6.1

1.8

0.0

None

-

-

-

28.1

29.9

35

35

E18

18

2

18.1

29.3

31.5

35

35

E24

24

2

24.1

36.5

38.7

40

40

E36

34

2

34.1

48.5

50.8

50

60

E54

54

2

54.2

59.6

61.8

70

70

1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.

ZJ078-150 Hi Static Motor - Without Powered Convenience Outlet (Continued)

Size

(Tons)

Volt

Compressors

(each)

OD Fan

Motors

(each)

Supply
Blower

Motor

Pwr
Exh

Motor

Pwr

Conv

Outlet

Electric Heat Option

MCA

1

(Amps)

MCA

1

w/Pwr

Exh

(Amps)

Max Fuse

2

/

Breaker

3

Size

(Amps)

Max Fuse

2

/

Breaker

3

Size w/ Pwr

Exh

(Amps)

RLA

LRA

MCC

FLA

FLA

FLA

FLA

Model

kW

Stages Amps

Advertising