Step 3. Enter the administrator password. The default is 1234
Step 4. Enter the command “bin” to set binary transfer type
Step 5. Use the command “put” to transfer files between the Prestige and the workstation. The file name
for the firmware is “ras” and for the configuration file “rom-0” (rom-zero, not capital o).
Figure 14-11 FTP Example
The system reboots after a successful upload.
Using FTP client software
Step 1. Rename the local firmware and configuration files to 'ras' and 'rom-0', because we can not
specify the remote file name in the FTP client software.
Step 2. Use FTP client from your workstation to the Prestige 480 and log in by entering the IP address of
the Prestige.
Step 3. Set the transfer type to 'Auto-Detect' or 'Binary'.
Connected to 480.x.x.x
220 P480 FTP version 1.0 ready at Thu Jan 8 18:00:02 1970
User (480.x.x.x:(none)): <Enter>
331 Enter PASS command
Password:
230 Logged in
ftp> bin
ftp> ha