background image

251933-YTG-J-1009

34

Johnson Controls Unitary Products

115°F

125°F

1250

77

54.7

6.1

22.5

17.8

13.2

-

-

-

50.3

6.7

19.5

15.9

11.3

-

-

-

72

49.8

6.0

30.4

25.8

21.2

16.5

-

-

45.6

6.6

28.3

23.8

19.3

14.7

-

-

67

44.9

5.9

38.3

33.7

29.1

24.5

19.9

-

41.0

6.5

36.3

31.7

27.2

22.7

18.1

-

62

41.4

5.9

41.4

41.4

35.3

30.7

26.1

21.4

38.2

6.5

38.2

38.2

32.7

28.1

23.6

19.0

1500

77

58.2

6.1

25.4

20.1

14.7

-

-

-

53.3

6.7

23.1

17.9

12.6

-

-

-

72

53.0

6.0

34.2

28.9

23.6

18.3

-

-

48.3

6.6

32.0

26.7

21.5

16.3

-

-

67

47.7

5.9

43.0

37.7

32.4

27.1

21.8

-

43.4

6.5

40.8

35.6

30.4

25.2

20.0

-

62

44.0

5.9

44.0

44.0

39.3

34.0

28.7

23.4

40.5

6.5

40.5

40.5

36.5

31.3

26.1

20.8

57

43.5

5.9

43.5

43.5

39.5

34.2

28.9

23.6

40.3

6.5

40.3

40.3

36.1

30.9

25.7

20.5

1750

77

61.6

6.1

28.3

22.3

16.3

-

-

-

56.2

6.7

26.6

19.9

14.0

-

-

-

72

56.1

6.0

38.0

32.0

26.0

20.0

-

-

51.0

6.6

35.6

29.7

23.8

17.9

-

-

67

50.6

5.9

47.7

41.8

35.8

29.8

23.8

-

45.8

6.5

45.4

39.5

33.6

27.7

21.8

-

62

46.6

5.9

46.6

46.6

43.4

37.4

31.4

25.4

42.7

6.5

42.7

42.7

40.4

34.5

28.6

22.7

57

46.1

5.9

46.1

46.1

43.6

37.6

31.6

25.6

42.6

6.5

42.6

42.6

40.0

34.1

28.2

22.3

2000

77

65.1

6.1

31.2

24.5

17.8

-

-

-

59.2

6.7

30.2

21.9

15.3

-

-

-

72

59.2

6.0

41.8

35.1

28.4

21.8

-

-

53.7

6.6

39.2

32.6

26.1

19.5

-

-

67

53.4

5.9

52.5

45.8

39.1

32.4

25.7

-

48.2

6.5

48.2

43.4

36.8

30.2

23.6

-

62

49.2

5.9

49.2

49.2

47.4

40.7

34.1

27.4

45.0

6.5

45.0

45.0

44.2

37.6

31.1

24.5

57

48.7

5.9

48.7

48.7

47.6

40.9

34.2

27.6

44.8

6.5

44.8

44.8

43.8

37.2

30.6

24.0

2250

72

60.1

6.0

44.8

37.5

30.1

22.8

-

-

54.3

6.6

42.0

34.8

27.6

20.4

-

-

67

54.2

5.9

53.7

48.8

41.4

34.1

26.7

-

48.7

6.5

48.7

46.2

39.0

31.8

24.6

-

62

50.0

5.9

50.0

50.0

49.1

41.7

34.4

27.0

45.5

6.5

45.5

45.5

45.1

37.9

30.7

23.5

57

49.4

5.9

49.4

49.4

48.9

41.5

34.2

26.8

45.3

6.5

45.3

45.3

44.8

37.6

30.4

23.2

2500

72

61.0

6.0

47.9

39.9

31.8

23.8

-

-

54.9

6.6

44.8

37.0

29.1

21.3

-

-

67

55.0

5.9

55.0

51.8

43.8

35.8

27.7

-

49.3

6.5

49.3

49.0

41.1

33.3

25.5

-

62

50.7

5.9

50.7

50.7

50.7

42.7

34.7

26.7

46.0

6.5

46.0

46.0

46.0

38.1

30.3

22.5

57

50.1

5.9

50.1

50.1

50.1

42.1

34.1

26.1

45.8

6.5

45.8

45.8

45.8

38.0

30.2

22.4

1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower

Performance Table for the kW of the supply air blower motor.

2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.

ZR060 (5.0 Ton) Cooling (Continued)

Air on

Evaporator Coil

Temperature of Air on Condenser Coil

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

Total

Capacity

1

(MBh)

Total
Input

(kW)

2

Sensible Capacity (MBh)

CFM

WB
(°F)

Return Dry Bulb (°F)

Return Dry Bulb (°F)

90

85

80

75

70

65

90

85

80

75

70

65