Xantrex Technology PH1800 User Manual

Page 54

Advertising
background image

Specifications

A–6

975-0288-01-01

10-amp Charging Profile

Table A-6 provides the specific charging parameters for the 10 Charging
Profile.

0-amp Charging Profile

When Charger Setting 0 A is selected, the Battery Charger is disabled and
will not charge the batteries. Use this mode if other DC charging sources
are available or if it is necessary to temporarily disconnect the AC
charging system.

Table A-6 10-amp Charging Profile

Parameter Name

Default Value

Charger Setting

10 A

Maximum Bypass Current

1200 W (10 A)

Bulk Mode

10 A

Absorption Mode

14.2 Vdc (4 hours maximum)

Float Mode

13.7 Vdc (8 hours)

Switches from Absorption to
Float Mode

4 A

Switches from Float Mode
back to Bulk Mode within the
8-hour limit, if the Float
current increases to 6 A.

6 A

Standby Mode (Off Mode)

12.5 Vdc

Estimated charging time

32 hours based on a single battery box with
two 100 Ah, 12 Vdc batteries and no other DC
charging sources