SpeciÐcation

15. Specification

15.1 Dimensions and connections

b02

c01

c06

470

100

414

40

117

20

225
140

35

368

30

338

47

b03

D00000

2

3

6

0

9

b02 Entry electrical cables I

b03 Entry electrical cables II

c01

Cold water inlet

Male thread

G 1/2 A

c06 DHW

outlet

Male thread

G 1/2 A

15.2 Wiring

diagram

3/PE ~ 380 - 415 V

8

5

_0

2_0

2

_0

0

0

5

1 Bare wire heating system
2 High limit safety cut-out
3 Safety pressure limiter

Priority control with load shedding relay (LR 1-A)

See also chapter “Appliance description / Accessories”.

8

5

_0

2_0

2

_0

0

0

3_

2
1

1 Control cable to the contactor of the second appliance (e.g.

electric storage heater).

2 Control contact opens when switching the instantaneous

water heater on.

15.3 Mixed water volume / outlet volume

The values are relative to a rated voltage of 400 V. The mixed water
volume and outlet volume are subject to the available supply pres-
sure and the available mains voltage.

Available temperature approx. 38 °C in the shower, for hand wash-
ing, filling the bath etc.

6

10

14

4

5

6

7

8

9

10

11

12

13

14

15

4

3

2

1

84

_0

2_

0

2

_0

0

3

8

Outlet temperature approx. 55 °C for the kitchen sink and when
using thermostatic valves.

2

3

4

5

6

7

8

9

10

6

10

14

4

3

2

1

84

_0

2_

0

2

_0

0

3

9

X Cold water inlet temperature in °C
Y Mixed water volume / outlet volume in l/min
1 HDB-E 12 Si
2 HDB-E 18 Si
3 HDB-E 21 Si
4 HDB-E 24 Si

Advertising