Installation speciðcation, 4 application areas, 5 pressure drop – STIEBEL ELTRON HDB-E Si 01.11.2012 - 31.01.2013 User Manual

Page 27: 6 fault conditions, 7 data table

Advertising
background image

EN

GL

ISH

www.stiebel-eltron.com

HDB-E Si |

27

INSTALLATION

SpeciÐcation

15.4 Application

areas

Specific electrical resistance and specific electrical conductivity

Standard

specification

at 15 °C

at 20 °C

at 25 °C

Resistance

Ω cm

≥ 1100

≥ 970

≥ 895

Conductivity

mS/m ≤ 91

≤ 103

≤ 112

Conductivity

μs/cm ≤ 910

≤ 1030

≤ 1120

15.5 Pressure

drop

Pressure drop at taps at flow rate of 10 l/min

Mono-lever mixer tap, approx.

MPa

0.04 - 0.08

Thermostatic valve, approx.

MPa

0.03 - 0.05

Hand shower, approx.

MPa

0.03 - 0.15

Sizing the pipework

When calculating the size of the pipework, a pressure drop for the
appliance of 0.1 MPa is recommended.

15.6 Fault

conditions

In case of faults, loads up to a maximum of 95 °C at a pressure of
1.2 MPa can occur temporarily in the installation.

15.7 Data

table

HDB-E 12 Si

HDB-E 18 Si

HDB-E 21 Si

HDB-E 24 Si

232003

232004

232005

232006

Electrical data

Rated output 1

kW

11.0

18

21

24

Rated voltage 1

V

400

400

400

400

Rated current 1

A

16

26

31

35

Fuse 1

A

16

25

32

35

Rated output 2

kW

10.1

16.2

19

21.7

Rated voltage 2

V

380

380

380

380

Rated current 2

A

15.4

24.7

29.5

33.3

Fuse 2

A

16

25

32

35

Rated output 3

kW

11,5

19,4

22,6

25,8

Rated voltage 3

V

415

415

415

415

Rated current 3

A

16

27

32,2

36,3

Fuse 3

A

16

32

32

40

Phases

3/PE

3/PE

3/PE

3/PE

Frequency

Hz

50/-

50/-

50/-

50/-

Max. mains impedance Zmax to DIN EN 61000-3-11

Ohm

0.33

0.33

Conductivity at 15 °C

mS/m

90.9

90.9

90.9

90.9

Specific resistance (≤25 °C)

Ohm cm

1100

1100

1100

1100

Connections

Water connection

G 1/2 A

G 1/2 A

G 1/2 A

G 1/2 A

Application limits

Max. permissible pressure

MPa

1

1

1

1

Values

Max. permissible inlet temperature

°C

25

25

25

25

On

l/min

> 2.3

> 2.3

> 2.3

> 2.3

Flow rate for pressure drop

l/min

3.1

5.2

6.0

6.9

Pressure drop at flow rate

MPa

0.07 (0.02 without

DMB)

0.08 (0.06 without

DMB)

0.10 (0.08 without

DMB)

0.13 (0.1 without

DMB)

Flow rate limit at

l/min

4

7.5

7.5

8.5

DHW delivery

l/min

5.5

9.0

10.5

12