Press [▲/▼] to scroll up or down to select the option.

„

Reset Opts.: Restore all setup values to factory defaults.

„

Delete AttLogs: Delete all transaction logs.

„

Clear All Data: Delete all users and logs. (Note: You will

lose all information stored on the terminal.)

„

Clr Admin Pri: Change all privilege levels to User.

„

Voice On? Turn voice prompts on or off.

„

Show Score: Show the degree to which a fingerprint reading

matches the stored template. 0 is the lowest score (no match) and
50 is the highest score (perfect match).

„

Match Thr: Set the fingerprint match threshold level. The

threshold value can be set 0 – 75 (default is 35). See Table 1-1.

„

Mst Input ID: Turns 1:1 (one to one) fingerprint verification on

or off.

„

1:1 Thr: The minimum fingerprint read correlation needed to

achieve a positive match for 1:1 verification.

„

Voice: Set the voice prompts on or off.

„

Upd Firmware: The user cannot update the firmware

unless this feature has been enabled by the manufacturer
or an authorized dealer.

„

Work Code: Enables/disables the work code feature on the clock.

If enabled, 4 Modes are available. Mode 1 and Mode 2 are not
supported. Use Mode 3 if you have timeQplus software and want
to use global list of work codes per company. Mode 4 allows to use
individually assigned work codes for employees (see timeQplus

Software).

„

Button Beep: Turn audible feedback on/off when pressing

buttons on the keypad.

„

Adj VOL(%): Adjust the volume level (0-99); “0” turns off the

speaker.