Channel, Trigger mode – EVS IPDirector Version 5.6 - May 2009 Part 1 User's Manual User Manual

Page 77

Advertising
background image

Issue 5.6.D

IPDirector Version 5.6 – User Manual – Part 1: General Workspace

EVS Broadcast Equipment – May 2009

66

Action Description

TALLY

Activates or deactivates the on-air flag on the selected
channel.

EXITASAP

Initiates a command to exit the loop as soon as possible
without playing the current element until its end and jump to
the selected element.

EXITOUT

Initiates a command to exit the loop as soon as the OUT point
of the current element is reached and jump to the selected
element.

NONE

No value is defined.

Channel

The Channel field allows the user to define the channel on which the GPI key
action will be executed. The possible values are:

a channel of the XT[2] server to which the GPI is physically linked

the ‘None’ value.

Trigger Mode

The Trigger Mode field allows the user to define the type of trigger signal that will
be sent by the GPI to the XT[2] server. The following trigger modes can be

defined:

Trigger Mode

Description

Pulse Rising Edge

The trigger is done on a rising edge pulse.

Pulse Falling Edge

The trigger is done on a falling edge pulse.

Level High

The trigger is done when the level changes to
high level

Level Low

The trigger is done when the level changes to
low level

None

No trigger mode is defined.

Note

If the operator selects ‘None’ for one of the fields, all three fields are
reset to ‘None’. It is considered that the GPI is not used.

Advertising