INSTALLATION INSTRUCTIONS

21

M S D

•   W W W . A T O M I C E F I . C O M   •   ( 9 1 5 )   8 5 5 - 7 1 2 3   •   F A X   ( 9 1 5 )   8 5 7 - 3 3 4 4

CLEAR FLOOD

If a flood condition occurs, turn the key on then press the accelerator to wide-open throttle. This tells

the ECU to turn off the injectors. Crank the engine to clear the flood condition until the engine starts

(release the throttle).

Note: The TPS is self calibrating so the key must be in the ON position prior to pressing the accelerator.