If not installing optional

thermocouple, skip to Section 5.

1.

The thermocouple monitors

the temperature of the exhaust

gases entering the turbocharger

at the turbine housing. Installation

requires that the exhaust manifold

be drilled near the manifold outlet.

It is recommended that the manifold

be removed from the engine to

thoroughly clean out all metal chips

from drilling. All metal shavings must

be cleaned from the manifold to avoid

turbine wheel damage and possible

interference with the turbocharger’s

variable geometry turbine stage.

2.

Disconnect the Exhaust Back

Pressure Sensor tap located at the

front of the driver side manifold. The

pressure tap must be removed by

using a

9

16

” open-end wrench to hold

the fitting stationary, and loosen the

tube using a

5

8

” open-end wrench.

The fitting is shown in Figure 30.
NoTE: Failure to hold the fitting

stationary will damage the tube upon

removal.

3.

Remove the driver side exhaust

manifold.

4.

Drill a

7

16

” hole in the driver side

exhaust manifold at the location

shown in Figure 31.

5.

Tap the hole for a

1

4

” NPT thread.

check the thread depth as you tap

by periodically removing the tap and

screwing the pipe coupling into the

tapped hole. The coupling should

thread in 3 to 3

1

2

turns hand tight. Do

not install the probe in place at this

time. Caution: Running the tap

too deeply can prevent the pipe

fitting from properly sealing.

6.

Remove the NPT fitting from the

thermocouple and install it on the

exhaust manifold. Use anti-seize

lubricant on the threads and torque to

14–16 lb-ft.

7.

Remove all metal chips from

the exhaust manifold. Note: Failure

to remove all metal chips could

result in catastrophic damage to

the turbocharger’s turbine wheel or

interfere with the operation of the

variable geometry vane mechanism.

8.

Re-install the exhaust manifold.

Apply anti-seize lubricant to the

manifold bolt threads and torque to

28 lb-ft. Use the tightening sequence

shown in Figure 32.

Section 4

OPTIONAL THERMOCOUPLE INSTALLATION

Figure 30: Location of the static exhaust pressure line tap

Advertising