8. Hopper Assembly
PNEG-257 12', 15', 18' and 21' Bulk Feed Tanks BFT and GHT Series
49
Hopper Collar Assembly
45° 22" Hopper collar (BLK-10854)
60° 22" Hopper collar (BLK-10342)
Install hopper collar before all hopper panels are assembled. Use 5/16" truss head bolts, as shown
, on all hopper seams. Be sure to caulk between the hopper collar and hopper panels.
Figure 8H Hopper Seam Overlap Detail
16" 45° Hopper extension panel (BLK-10697) (three (3) required)
16" 45° Hopper collar (BLK-10696)
16" 60° Hopper extension panel (BLK-10487) (three (3) required)
16" 60° Hopper collar (BLK-10489)
Before last hopper panel is attached, assemble the hopper extensions (if utilized) on the hopper collar.
Use 5/16" truss head bolts and caulk all joints on the hopper extensions and collar. After completing this
assembly, attach to the hopper panels, using 5/16" truss head bolts. Be sure to caulk between hopper
extensions and hopper panels.
Figure 8I 22" Hopper Collar