RELEASE DATE: October 4, 1999

1) Attempted to fix the problem of grain setpoint changing by itself.
2)

Fixed problem of batch dryer always shutting down with a "DRYING CHAMBER EMPTY" warning. A delay called the "REFILL TIMER" allows the
dryer to fill back up.

*********************************************************************
VERSION: 2.00

REVISED BY: Jeff Falconer

RELEASE DATE: January 6, 1999

1) Fixed hour timer so dryer will now show running time of dryer.
2)

Changed the way the dryer shut down when using the dry and hold switch, now it will cool the grain using the cool timer before it shuts down to prevent heat

buildup of grain past the grain temp set points thereby causing a shutdown condition. Works in Autoflow and AutoBatch modes.

3) Fixed the clock to properly roll over in the year 2000.
4)

Added a user batch count and user timer independent from the Total batch and Total time

allowing monitoring of different users drying grain or different

fields for comparison of drying time.

5)

Added a test procedure for the keypad. Turning all of the control switches to the right (on position) and holding in the stop switch while turning on the

control power activates it. User can now test each individual keypad switch for malfunction or stuck keys. (Taken out in 2.03)

6)

Added control switch testing by pressing and hold the plenum and grain switches in while turning on the control power. This will allow the user to test for

failed switches or computer failure to detect switch position changes. (Changed in 2.03 to turn power on with Help key depressed)

7) Removed garbage displayed when user selected to view total running time and total batches.
8)

Added a check to make sure the dump switch is always in the Auto posistion. Otherwise if left in manual close will cause the dryer never to dump.

9) Fixed several bugs that were reported to use by users and dealers.
10) I added the ability to

reset the Total Dryer running time by pressing the HOUR and RESET button together and turn on the dryer.

11)

Removed watchdog option in Extended setup mode since watchdog has not been implemented yet.

12) Changed the wording to some of the error messages concerning the rotary switches to help eliminate some confusion of which switch was at fault.
13)

Moisture control light will now flash to give a visual indication that the dryer is in temperature hold.

*********************************************************************
VERSION: 1.06

REVISED BY: STEVE LOGUE

RELEASE DATE: November, 98

1.)

Fixed dryer so the grain hi limit occurs at 20 F above the grain temp setpoint.

2.) Made timeout on the open/close of the actuator 20 seconds instead of 15 seconds. This extra time was added to compensate for the weaker batteries taking

longer to close the chutes.

*********************************************************************
VERSION: 1.05

RELEASE DATE: September, 98

1.) Made the out of grain timer active.
*********************************************************************
VERSION: 1.04

RELEASE DATE: July, 98

1.)

The application of 12v to terminal number j1-20 will shutdown the dryer and give an indication that the bin is full due to the high level of static pressure

within."BIN AIR PRESSURE LIM" will be displayed on screen's top line until the user corrects the problem.

(Originally looked for lack of 12v, fixed in

2.00

)

2.) Corrected the hour meter problem.
3.)

Changed how the dry timer is displayed: Now when the dry timer goes to zero it will begin counting upward at the user set time as long as the dryer remains

in temp hold.

*********************************************************************
VERSION: 1.03

RELEASE DATE: March, 98

1.)

Added software to allow the aeration fan to continue running even if there was a dryer shutdown. The aeration fan BYPASS mode must be selected under

setup

.

*********************************************************************
VERSION: 1.02

RELEASE DATE: Jan, 98

1.)

The Bin high limit rotary switch is monitored in both states to insure that a switch failure has not taken place. If both switches are in the same state a switch

failure is reported.

*********************************************************************
VERSION: 1.01

RELEASE DATE: NO OFFICIAL DATE ASSIGNED

1.)

Added burner differential adjustment to be set at master under extended setup.

2.)

Gary Woodruff's software for holding the fans off during a portion of the dry cycle. This is adjusted under delays.

3.) Attempted to make the dryer dry remaining grain when a wet supply empty error takes place.
4.)

Added software to display a negative incrementing counter, where the dry timer used to be, during temp hold. (Changed in 1.04)

*********************************************************************
VERSION: 1.00

RELEASE DATE: SEPTEMBER 16, 1997

1.) We changed resistor number 107 on the display board from 10K to 3.0K to allow the contrast to work without resetting the computer.
2.). Put in a

contrast adjustment for the display. While turning the control power on, hold in on the screens key, and this will enter the contrast adjustment mode.

Now use the UP/DOWN arrow keys to adjust.

If the screen is solid black press the down arrow key, if nothing appears on the screen press the up arrow

keys. NOTE: You cannot hold in on the UP/DOWN arrow keys to adjust, you must continue to press and then release them or nothing will happen.

3.)

Put Software in for 3

rd

Fan and Heater.

*********************************************************************
VERSION: 0.05

RELEASE DATE: 1996

This was the first version released for customer operation. This particular version could only control 2 Fan and Heaters.