2003 top dry service school – Grain Systems PNEG-1314 User Manual

Page 16

Advertising
background image

2003 Top Dry Service School

1 6

SECONDS -- EXIT THE PROGRAM MODE.

0.22 Released OCTOBER 22, 1996
------------------------------------------------------------
1) FIXED THE PROBLEM WHERE IF YOU SET IN 3.2 HOURS -- THE HOURS IMMEDIATELY WENT TO .32 WHEN YOU
EXITED THE PROGRAM
MODE

2) *CLEARING OF THE NOVRAM IS NOW ACCOMPLISHED BY POWERING UP WITH THE PROGRAM SWITCH HELD
DOWN ( LOWER LEFT *
*SWITCH ) -- WHEN THE " 0 " COMES UP -- ENTER A " 7 " WITH THE INCREMENT SWITCH -- THEN PUSH THE
PROGRAM SWITCH AGAIN *
*" - - - " COMES UP -- YOU HAVE 2 SECONDS TO DEPRESS THE INC DEC SWITCHES AT THE SAME TIME TO
CLEAR THE NOVRAM *

0.21 Released OCTOBER 2, 1996
------------------------------------------------------------
1) FIXED THE PROBLEM THAT I CREATED IN VERSION # 0.20 WHERE THE ERROR 3 CAME ON -- SPARE
TEMPERATURE OPEN
2) WHEN IN TOP DRY MODE THE CYCLE FLAG IS ALWAYS SET

0.20 Released SEPTEMBER 12, 1996
------------------------------------------------------------

1) CREATE A NEW MODE THAT WILL MAKE IT SO THAT BOTH THE GRAIN TEMPERATURE MUST EXCEED THE
LIMIT AND THE DRY TIME
MUST BE EXCEEDED BEFORE ADVANCING TO THE COOL CYCLE ON THE TOP DRY

2) IF THE GRAIN TEMPERATURE GETS TO 200 -- ALWAYS ADVANCE TO THE COOL CYCLE -- IN ALL MODES OF TOP
DRY, ---> IF THE 10
MINUTE GRAIN TIMER HAS GONE TO 0.
3) FIXED PROBLEM ( I THINK ) WHERE THE TEMPERATURE WOULD MOMENTARILY JUMP UP TO 275 DEGREES --
WHEN THE THERMISTOR
SWITCH-OVER OCCURED ON THE BOARD

0.19 Released JUNE 8, 1996
------------------------------------------------------------
1) HUMIDITY SOFTWARE

0.18 Released MARCH 13, 1996
------------------------------------------------------------

1) DON'T ADVANCE TO COOL CYCLE IN TOP DRY MODE FOR 10 MINUTES AFTER STARTING THE DRYER
-- ALLOW THE GRAIN TEMPERATURE SENSOR TO STABILIZE

2) WHEN THE SLAVE POWERS UP WITH THE FAN ON -- THERE WAS A LOT OF DISPLAY FLICKER -- CORRECT THAT
PROBLEM

0.17 Released OCTOBER 17, 1995
------------------------------------------------------------
1) FIXED THE PROBLEM WITH THE TOP DRY MASTER NOT SHUTTING THE FAN OFF WHEN THE SLAVE GOT AN
ERROR
2) WHEN GETTING ONE OF THE LIMIT ERRORS, ETC -- THAT JUST DISPLAYS A LEGEND -- ON THE MAIN DISPLAY
INSTEAD OF DISPLAYING
TEMPERATURE --

DISPLAY: 0 0 0

ERROR

0.16 Released OCTOBER 16, 1995
------------------------------------------------------------
1) Raised the Error 12 Voltage Limit from >155 to >195 volts for 120 volt systems. <155 volts still the error 12 limit for 240 volt
systems.

0.15 Released OCTOBER 14, 1995
------------------------------------------------------------
1) CORRECTED THE PROBLEM WHERE WITH CERTAIN ERRORS YOU COULD NOT VIEW THE AMOUNT OF TIME
THE DRYER HAS BEEN
DOWN DUE TO ERROR CONDITION
2) IF THE " STANDARD DRYER " ( NOT TOP DRY ) FINDS A SLAVE INCONSISTANCY ERROR -- ERROR # 9, 10 O 11 --
IT WILL TRY RESTARTING
THE SLAVE FOR 5 SECONDS BEFORE IT GIVES UP
3) CORRECTED THE BUG IN VERSION 14 SOFTWARE WHERE THE REMAINING HOURS WERE NOT STORED FOR
DRY AND COOL TIME -- ALL

Advertising