39

2001 Top Dry Service School

Software Changes

Significant Software changes since July 12, 1995,continued

(Software version number is displayed at all units on power-up)

Series 2000 Batch Software Changes

¨

Software Version 0.22

When setting the dry time to 3.2 hours

the display would say .32 hours when

the program mode was exited - fixed

that problem.

Clearing the NOVRAM is now down

by powering up with the program

temperature switch held down, press

the increase switch until a 7 is dis

played and press the program tempera-

ture switch again. You have two

seconds to press the increase and

decrease switches at the same time to

clear the NOVRAM.

¨

Software Version 0.21

When in the Top Dry mode the heater

is always set up as a hi-lo fire unit.

¨

Software Version 0.20

Created a option in the set-up mode: L or no L

If L is selected, the dryer timer has to be at zero

and the grain temperature has to be at the

desired set point before the unit will advance to

the cool cycle.

If noL is selected, the dry timer has to be at zero

or grain temperature has to be at the desired set

point before the unit will advance to the cool

cycle.

If the grain temperature exceeds 200 degrees F,

after the initial 10 minutes of the dry cycle, the

dryer will advance to the cool cycle.

In some instances the plenum tempera-

ture would jump to 275 degrees F -

fixed that problem.

¨

Software Version 0.19

Added software for a humidity sensi-

tive controller.

¨

Software Version 0.18

The dryer will not advance to the cool cycle for

at least ten minutes after start-up. This allows

the grain temperature sensor to stabilize.

Fixed a problem with display flicker on two fan

units.