2001 Top Dry Service School
46
Software Changes
Significant Software Canges
(Software version number is displayed at all units on power-up)
Series 2000 Autoflow Display Software Changes
VERSION: 2.02
1)
Changed the Batch percentage off selection screen to a screen which allows you to enter a
time (just like any other timer) at which the dryer will shut off loading in the DRY TIME. The
timer is called the BATCH FILL TIME.
VERSION: 2.01
1)
Attempted to fix the problem of grain setpoint changing by itself.
2) Fixed problem of batch dryer always shutting down with a DRYING CHAMBER EMPTY
warning. A delay called the REFILL TIMER allows the dryer to fill back up.