2001 Top Dry Service School

Software Changes

Significant Software Changes

(Software version number is displayed on power-up)

Series 2000 Autoflow Display Software Changes

VERSION: 2.10

1)

Changed the Minimum Burner Differential to 1 Deg. Fahrenheit

2)

Fixed the problem where the burner was not shutting off when the Dry & Hold switch was

placed in the “On” position, the Dry Cycle was complete, and the Dryer was in the Cool Cycle. Now,

when the Dry & Hold switch is placed in the “On” position, and the Dry Cycle is complete, the dryer

will shut the burner off and will cool for the amount of time on the Cool Timer before stopping.

3)

Fixed a problem where the dryer was not shutting down with an “Out of Grain” error when the

Wet Supply Rotary Switch was exposed. Now when the Wet Supply Rotary Switch is exposed, the Fill

#1, andFill #2 delay will count down and shut off Fill System #1 & #2, then the dryer will shut down

with an “Out of Grain” error. If there is still grain against the Low Level Rotary Switch, the dryer can be

restarted by pressing the Stop switch to clear the error, turning the Load Auger switch to the “Off”

position, and pressing the Start switch. When the Start switch is pressed the screen will say “Press

<Enter> to Dry Remaining Grain”. If the <enter> button is pressed the dryer will restart.

NOTE: If the Load Auger switch is left in the “Auto” position an “Out of Grain” error will be given on

startup.