Initializing the Novram
Turn the Control Power off .
Hold down the Program Temperature
switch.
Turn the Control Power switch on
with the Program Temperature switch
held down.
Press the Increase switch until 7 is on
the display.
Press the Program Temperature switch
again.
You have two seconds to depress the
Increase or Decrease switches at the
same time.
The NOVRAM has been initialized.
NOTE: The computer has now been cleared of
all memory, including the type of dryer it is and
all Set-up variables.