Series 2000 autoflow display software changes – Grain Systems PNEG-1135 User Manual

Page 42

Advertising
background image

2001 Top Dry Service School

42

Software Changes

Significant Software Changes

(Software version number is displayed on power-up)

Series 2000 Autoflow Display Software Changes

VERSION: 2.11

1)

Burner differential would not stay at 1 deg. F when the dryer

was turn off, using 2.10, now it does.

2)

When grain reaches the Storage Chamber Rotary Switch, the dryer will enter a

“Cool Down Mode”. The fan will run and cool the grain for 10 minutes before

shutting down due to a Storage Chamber Full error.

3)

When grain falls away from the Wet Supply Rotary Switch, the dryer will enter a

“Cool Down Mode” after the fill system shut off. The fan will run and cool the

grain for 10 minutes before shutting down due to a No Wet Supply error.

4)

When the Dry & Hold switch is placed in the “On” position the dryer will enter

a “Cool Down Mode” for 20 minutes before stopping. This only happens at the end

of the dry cycle.

5)

Corrected a problem with the Fans Off Delay. If there is time on this delay,

the fans and heaters will shut off during the unload cycle, after the unload cycle

is complete the delay counts down. The fans and heaters will not start again until

the delay has reached zero.

6)

Corrected a problem with the Time Until Load Off percentage set in the set-up mode.

Now, in Autobatch only, the Fill Systems will shut off if grain has not reached

the dry chamber high level rotary switch within the set percentage of the dry timer

is completed. Example: 1 hr dry time, 50% Time Until Load off. The fill systems

will shut off regardless of rotary switch status after 30min has expired.

7)

Corrected a problem with the Refill Delay. Now, in Autobatch Only. The Refill

Delay begins to count down after the unload cycle is completed. If grain has not

reached the drying chamber low level rotary switch before this delay reaches zero,

a dry chamber empty error is given.