Series 2000 autoflow display software changes – Grain Systems PNEG-1135 User Manual

Page 44

Advertising
background image

2001 Top Dry Service School

44

Software Changes

Significant Software Canges

(Software version number is displayed at all units on power-up)

Series 2000 Autoflow Display Software Changes

VERSION: 2.09

1)

Selection screen for On-Off burner. This cannot be used in conjunction with diesel burner.

NOTE: Must change heater software also. Use following version number or higher:

Heater ==> 1.09

VERSION: 2.08

1)

Changed the burner differential setup screen to correctly display Celsius temperatures.

2)

Now only a year above 2000 may be entered upon setting the date.

3)

Burner differential is now greater than 1 and less than 10 degrees.

VERSION: 2.07

1)

Changed the checksum method for the network to help insure data integrity.

2)

Force aeration fan to start before drying fans start, unless aeration switch is in off position.

3)

Load systems cannot start for five seconds after start of system.

NOTE: Must change heater and I/O software also. Use following version number or higher:

Heater ==> 1.07

IO

==> 1.07

VERSION: 2.06

1)

Stopped the ability to change the grain setpoint from heaters.

VERSION: 2.05

1)

Fixed a problem with fan 1 reporting air switch already engaged if fan 2 had not started yet.

2)

Fixed the low level disabling software so a warning is not reported when the high level grain

switch detects grain without the low level detecting grain.

VERSION: 2.04

1)

Made all airswitches active once again.

Advertising