background image

4. Installation

PNEG-1894 Top Dry Chute Controller

11

Attaching the Mounting Plate and Gussets to the Stiffener

1. Position the bottom edge of the stiffener mounting plate 13" from the bottom of the stiffener.

2. Field drill all six (6) holes in the stiffener using the mounting plate as a template for hole locations,

making sure that the holes are drilled on the peaks of corrugation ridge.

3. Attach the stiffener mounting plate (A) using six (6) bolts (B) and nuts (C).

(See Figure 4D.)

Figure 4D

Ref #

Part #

Description

A

TD-101327

Stiffener Mounting Plate

B

S-7515

Bolt, HHCS 3/8"-16 x 1-1/2" Grade 5

C

S-7383

Nylock Nut 3/8"-16 Zinc Grade 5