6. Installation

PNEG-1128 Chain Loop System without Controls

33

Ground Control Kit for Discharge Gates (Continued)

Each control system should be marked to identify which discharge gate is being controlled.

Each control system should be marked after installation to clearly identify whether the discharge gate is
open or closed.

Set screws in the ground control wheel can be used to lock the wheel in position to prevent accidental
opening or closing of the discharge gate.

Assemble the idler pulleys to the mounting bracket on the inside surface if the cable is going to a discharge
gate on the same bin. Assemble them on the outside if the cable is going to an adjacent bin. Attach the
idler pulley bracket to the bin wall just under the eave to ensure that the cable will clear the bin roof.

Attach the ground control wheel bracket to the bin wall directly below the idler bracket. Assemble the
wheel-mounting bracket loosely to the wall bracket and slide it up as far as possible. Assemble the control
wheel to the shaft and secure with cotter pins.

(See Page 35.)