Bga socket, Surface mount) assembly instructions, Recommended reflow profile – Ironwood Electronics GHZ BGA Socket (Surface Mount) Assembly Instructions User Manual

Page 2

Advertising
background image

GH

Z

BGA Socket

(surface mount)

Assembly Instructions

© 2000 IRONWOOD ELECTRONICS, INC.

Tele: (800) 404-0204

www.ironwoodelectronics.com

page 2 of 2

250

200

150

100

50

0

100

200

300

400

500

Preheat

Flux Activation

Reflow

Cool-Down

<2°C

per Second

150 - 180 Seconds

<2°C

per Second

1° to 3°C

per Second

Time (seconds)

T

e

m

p

er

atu

re (°C

)

Maximum Package Body Temperature

Solder Temperature Melting Point

Recommended Reflow Profile

1. Use caution when profiling to insure minimal temperature difference (<15 C and preferably <10 C) between components

2. Forced convection reflow with nitrogen preferred (optional)

3. Preheat stage temperature ramp rate: <2 C per second

4. Time required in Flux Activation stage: 150 to 180 seconds

5. Flux Activation stage temperature range: 150 to 183 C

6. Time required in Solder stage: 60 seconds

7. Maximum temperature 210 - 220 C (Do not exceed 10 seconds at maximum temperature)

8. Cool-Down stage temperature reduction rate: <2 C per second

NOTE:
It may be necessary to adjust the amount of heat when attaching the part, due to the fact that
the adapter mass is different from the actual IC package. Solder sphere spec = 63Sn, 37Pb
and its melting point = 183 C

Filename: HSI.mcd, Rev A, 1/18/00, IP