OSRAM OPTOTRONIC Constant current LED power supplies with 3DIM User Manual

Page 16

Advertising
background image

16

LEDset APPLICATIONS

Control line

Supplier

230 V

AC

Low voltage

OMRON

G2R1Z230VAC

G2R1AP3230VAC

G5V1 series (one contact pole)

G6S series (golden-plated – 3 V, 5 V, 12 V, 24 V)

PANASONIC

PA(D)1a series (bifurcated – 3 V, 5 V, 12 V, 24 V)

Switching can be carried out either by a switch (manual

activation, see fi gure 7a) or by using a relay (see fi gure 7b).

While Rset

1

sets the current level Iout

1

, the equivalent parallel

resistance Rset

EQ

(Rset

1

||Rset

2

) sets Iout

2

.

Note: In both cases (7a and 7b), two main issues need

to be considered when selecting the components:

Performance

The relay contacts or switch contacts must be suitable for

applications with a very low current. Selecting the right

type (low contact resistance, oxidation-proof etc.), i.e.

golden-plated or bifurcated contacts, is therefore essential.

Safety/SELV (Separated or Safety Extra-Low Voltage)

In case of SELV systems, insulation between contact cir-

cuit and actuator part – the human fi nger (7a) or the coil

of the relay (7b) – must be considered. For example, if

the relay control line is in some way referred to the mains

potential, a double insulation must be provided between

the coil circuit and the contact side of the component so

that the SELV property of the system is ensured. In case

of a control line that is already double-insulated from the

mains, a standard low-cost signal relay can be used.

In any case, please refer to the safety standard EN

61347-2-13 for ECG requirements and to EN 60589-1

for luminaire requirements.

For a relay-based solution (see fi gure 7b) where the control

line is not galvanically insulated from the mains or the mains

potential, the following relays can, for example, be used:

The use of double-contact or/and bi-stable relays extend

the confi guration possibilities of the LEDset interface

(more current steps, pulse-based relay control line etc.).

Table 5: Step dimming by resistor – suitable relays.

Advertising