LEDset APPLICATIONS

3.2.2.3. General notes on local dimming:
LEDset, “current set” combination

For some applications, the turn-off capability provided by

the LEDset characteristic above 11 V might not be an

appro priate feature.

Therefore, some LEDset ECGs can combine the LEDset

interface with the so-called “current set” (CS) feature.

Product examples are the OT 35/220-240/700 LTCS and

OT 45/220-240/700 LTCS (LTCS means “LEDset” (LT)

and “current set” (CS)).

On those devices, it is possible to set the current control

functionality by dip switch to work with a “pure” LEDset

interface as described in chapter 2, or to combine it with a

current set (CS) confi guration: 350, 500 and 700 mA where

the maximum nominal currents (Inom

max

) can be selected.

The Vset signal can still be used to control/set the output

current of the ECG as in a “pure” LEDset control –

with the difference being only in regards to the Vset charac-

teristic above 11 V.

A typical characteristic of this confi guration is shown in

fi gure 11.