9

LEDset SPECIFICATIONS

2.3. Technical details

2.3.4. Insulation

2.3.1. Bias current (Iset)

2.3.2. +12Vset

2.3.3. Fault protection

This chapter gives a general overview of the technical details

of the LEDset interface. For further details and deviations

from this basic information, please refer to the datasheet

and instruction sheet of the respective control gear.

All ECGs with LEDset interface have the following minimal

insulation barriers:

There is no galvanic insulation between the LEDset interface

and the secondary circuit.

Note: If the LEDset ECG is to be used in a system that must

be classifi ed as SELV (Safety Extra-Low Voltage), any circuit

connected to the LEDset interface of an SELV or SELV-

equivalent control gear can only be used if double-insulated

from the mains.

The LEDset interface has no specifi c protection against elec-

trostatic discharge (ESD). Therefore, it is recommended that

any circuit (e.g. accessible potentiometer) connected to the

LEDset interface port has a proper insulation against touch-

able parts.

Moreover, the negative pole of the LED load (LED-) must not

be connected to the GNDset terminal.

The LEDset interface is an active interface since the Vset in-

put can actually generate a constant current output (bias

current), allowing the Vset voltage to be achieved through

“passive” circuits (e.g. current setting by resistor, light sen-

sors etc.).

The integrated current generator provides a very stable bias

current (Iset) of 274 µA over the complete operating range of

the control gear. Thanks to this feature, unwanted current

variations due to temperature changes, which occur in many

ECGs with similar control interfaces, can be avoided.

The stabilized 12 V auxiliary voltage is able to supply a

current of up to 15 mA (laux). The voltage accuracy is within

a tolerance of ±10 %. A future power extension will provide

an even greater capability to supply more powerful loads

(such as an external fan for active cooling applications).

For details regarding the maximum allowable output power,

please refer to the datasheet and instruction sheet of the

respective control gear.

The +12Vset is protected against short circuit (+12Vset –

GNDset). Vset is protected up to the 12 V + 10 %.

Table 2: Insulation barriers of LEDset ECGs.

Primary

circuit

Secondary

circuit

LEDset

Primary

circuit

Depending

on the ECG

Depending

on the ECG

Secondary

circuit

Depending

on the ECG

No insulation

LEDset

Depending

on the ECG

No insulation

Advertising