Primary & hidden controls, Parameter ranges & default values, Display panel – Universal Audio UAD Plug-Ins ver.7.5 User Manual

Page 191

Advertising
background image

UAD Powered Plug-Ins Manual

- 191 -

Chapter 18: Lexicon 224

When configured as mono-in/mono-out (“MIMO”), output A is used exclu-
sively except in programs 2, 4, and 9, where outputs A and C are summed
into one monophonic signal. This implementation is recommended in the orig-
inal hardware manual. If Rear Outs is enabled in MIMO mode, outputs B and
D are used instead of A and C. See

Table 17 on page 205

for a list of outputs

used with each program in this configuration.

Primary &

Hidden Controls

The primary controls (those that are most typically used) are on the main “re-
mote control” panel interface. Additional (less typically used) controls are
available in a hidden control panel. The hidden control panel (

Figure 63 on

page 200

) is accessed by clicking the “OPEN” text label to the right of the

Display Panel.

For detailed descriptions of all parameters, see

“Primary Controls” on

page 193

and

“Hidden Controls” on page 200

.

Parameter

Ranges &

Default Values

The parameter value ranges, default values, and availability of particular pa-
rameters within a given program may vary depending on which program is
active. Parameter ranges are listed in the individual control descriptions. De-
fault parameter values for each program are listed in

Table 18 on page 205

.

Note:

Extreme parameter settings can cause Lexicon 224 to self-oscillate or

cause other unexpected sounds. This behavior is identical to the original hard-
ware.

Display Panel

The Lexicon 224 display panel (

Figure 61

below) consists of four display el-

ements: Numerical Value, LED Value, Stereo Level Meters, and Overflow in-
dicator. Exactly what is displayed here is dependent on the parameter being
edited (if any) and the state of the

Display Hold

switch (

page 202

).

Numerical Value

The three-character Numerical Value Display shows the value of parameters
as they are being edited. The value of the edited parameter is displayed for
1.5 seconds unless the

Display Hold

switch is set to infinite, in which case the

last edited parameter value continues to be displayed.

Figure 61. The Lexicon 224 Display Panel