10 GigaBit In-Line Regeneration Tap

Connecting to Monitoring Devices
Using Net Optics Custom Monitoring Cable

The Monitor Ports of the Regeneration Tap are transmit only . Connect the

Monitor Ports to the receive side of two NICs on the monitoring device .

Net Optics offers a custom “Y” cable with the correct connections for quick

installation . The SC connectors on the Custom Monitor Cable contain Rx

connections only. The Tx connectors do not have fiber and provide a safe

cover for laser light .
To connect a Custom Monitoring Cable:
1 . Using a Net Optics Custom Monitor Cable (see Figure 5), connect the

single-duplex end to the Regeneration Tap Monitor Port A or B .

2 . Connect the twin-duplex end of the cable labeled into the

appropriate monitoring device port to monitor the link (see

Figure 7).

3 . Connect the other twin-duplex end to the appropriate monitoring

device port to monitor the link .

4 . Repeat steps 1-3 for each monitoring device you wish to connect

to the Regeneration Tap .

Figure 5: Net Optics Custom Monitor Cable

DTE

DCE

To Monitor NIC Rx

To Monitor NIC Rx

To Monitor Port

Rx Disabled

Rx Disabled

Tx

Tx