Diodes AP3988/89/90 User Manual

Page 7

Advertising
background image

AP3988/89/90

Document number: DS36722 Rev. 3 - 2

7 of 13

www.diodes.com

March 2014

© Diodes Incorporated

AP3988/89/90

A Product Line of

Diodes Incorporated

N

E

W

P

R

O

D

U

C

T

Operation Description

(Cont.)


Constant Primary Peak Current

The primary i

p

(t) current is sensed by a current sense resistor R

CS

as shown in Figure 1.


The current rises up linearly at a rate of:

M

b

L

t

V

dt

t

di

)

(

)

(

ulk

p

………

(1)

i

p

(t)

0A

See equation 2

I

PK

Figure 2. Primary Current Waveform


As illustrated in Figure 2, when the current i

p

(t)

rises up to I

PK

, the switch Q1 turns off. The constant peak current is given by:

CS

CS

PK

R

V

I

………

(2)


The energy stored in the magnetizing inductance L

M

each cycle is therefore:

2

g

2

1

PK

M

I

L

E

………

(3)


So the power transferring from input to output is given by:

SW

PK

M

f

I

L

P

2

2

1

………

(4)


Where f

SW

is the switching frequency. When the peak current I

PK

is constant, the output power depends on the switching frequency f

SW

.

Constant Voltage Operation

The AP3988/89/90 captures the auxiliary winding feedback voltage at FB pin and operates in constant-voltage (CV) mode to regulate the output

voltage. Assuming the secondary winding is master, the auxiliary winding is slave during the D1 on-time. The auxiliary voltage is given by:

d

S

AUX

AUX

V

V

N

N

V

O

………

(5)


Where V

d

is the diode forward drop voltage, N

AUX

is the turns of auxiliary winding, and N

S

is the turns of secondary winding.

See equation 5

V

AUX

0V

Portion of T

ons

T

ons

Figure 3. Auxiliary Voltage Waveform

The output voltage is different from the secondary voltage in a diode forward drop voltage V

d

which depends on the current. If the secondary

voltage is always detected at a constant secondary current, the difference between the output voltage and the secondary voltage will be a fixed V

d

.

The voltage detection point is portion of T

ons

after D1 is turned on. The CV loop control function of AP3988/89/90 then generates a D1 off-time to

regulate the output voltage.