Hazardous machinery

can cause personal

injury or death.

WARNING

Extreme heat can

cause personal injury

or property damage.

WARNING

WARNING

DO NOT OPERATE UNIT WITH-

OUT SAFETY GUARD IN PLACE.

TO DO SO CAN CAUSE SEVERE

PERSONAL INJURY.

NOTICE: PUMP MUST BE COMPLETELY PRIMED

BEFORE OPERATION.

DO NOT OPERATE PUMP AT OR

NEAR ZERO FLOW. TO DO SO

CAN CAUSE EXTREME HEAT,

DAMAGE TO THE PUMP, INJURY

OR PROPERTY DAMAGE.

Start the pump, keeping the on-off valve down-

stream from the pump closed. Open the on-off valve

gradually. The pump must run smoothly and noise-

lessly. If necessary, reprime the pump. Check the cur-

rent absorbed by the motor and, if necessary, adjust

the setting of the thermal relay. Any air pockets

trapped inside the pump may be released by loosen-

ing the air screw for all e-SV pumps.

If a pump installed in a location where

freezing may occur remains inactive, you

must drain it through the drain plugs. This opera-

tion is not necessary if a suitable antifreeze has been

added to the water.

Make sure that the drained liquid does not

cause damage or injuries.

After stabilizing the system at normal operating

conditions, check piping for correct alignments. If

necessary, adjust pipe supports.

HAZARDOUS MACHINERY.

MOTOR THERMAL PROTEC-

TORS CAN RESTART MOTOR

UNEXPECTEDLY AND WITH-

OUT WARNING, CAUSING

SEVERE PERSONAL INJURY.

See the “ENGINEERING DATA” section in this

manual for the recommended maximum pump starts

per hour.

DISCONNECT AND LOCKOUT

ELECTRICAL POWER BEFORE

ATTEMPTING ANY MAINTE-

NANCE. FAILURE TO DO SO

CAN CAUSE SHOCK, BURNS OR

DEATH.

Check pump rotation by observing the motor fan or

the coupling THROUGH the coupling guard. DO

NOT confuse the flow arrows, stamped on the pump

body, with the rotation arrows on the coupling and

motor adapter. Three phase motors only – If rotation

is incorrect, have a qualified electrician interchange

any two of the three power cable leads.

3. PRIMING/VENTING

For installations with the liquid level above the pump:

Close the discharge valve.
Remove the vent plug.
For models 1SV, 3SV and 5SV only, it is neces-

sary to fully unscrew the pin located in the

drain plug. See figures below.

For sizes 10SV-125SV the vent plug is supplied

with an internal needle valve, so it is not neces-

sary to remove the vent plug. Simply unscrew

the needle valve half way to open the valve to

allow air to escape. (For sizes 33SV-92SV, if the

pump is supplied with a cartridge seal, remove

the vent plug located on the gland plate beneath

the coupling.)
Open the suction valve until liquid flows out of

the vent plug opening.

NOTICE: DO NOT REMOVE AND REPLACE DRAIN

PLUG WITH ANOTHER PLUG OR PIPING

FIXTURE FROM ANY OTHER MANU-

FACTURER, OR SIGNIFICANT LOSS OF

PUMP PERFORMANCE MAY OCCUR AS A

RESULT.

NOTE: Place a loose rag over the open vent port to pre-

vent large amounts of liquid from being sprayed

on the pump and adjacent equipment.

Care should be exercised if you are pumping

hot water or chemicals to avoid personal injury.
Install and torque the vent plug to the values

provided in the “ENGINEERING DATA” sec-

tion of this manual. Close the drain plug pin

(1SV, 3SV and 5SV only) and open the dis-

charge valve.

For installations with the liquid level below the pump:

Install foot valve at suction end.
For models 1SV, 3SV and 5SV only, it is

necessary to fully unscrew the pin located in the

drain plug. See figures above.
With the provided plastic funnel, completely fill

the casing with liquid.
Install and torque the vent plug, close the drain

plug pin (1SV, 3SV and 5SV only) and open the

suction valve.

WARNING

Hazardous

machinery

WARNING

Hazardous

voltage

DRAIN PLUG

WITH PIN CLOSED

DRAIN PLUG

WITH PIN OPEN