Xylem IM228 R03 Model e-SV (esv) User Manual

Page 16

Advertising
background image

16

WARNING

Hazardous

voltage

TORQUE VALUES

HP

Motor Bolt

Adapter Flange

Coupling

1-5SV

10-22SV

33-92SV

0.75-7.5 HP 20 lbs ft (27 N·m)

15 lbs ft (20 N·m) 40 lbs ft (54 N·m) 37 lbs ft (50 N·m)

10-75 HP 45 lbs ft (61 N·m) 48 lbs ft (65 N·m)* 15 lbs ft (20 N·m) 40 lbs ft (54 N·m) 48 lbs ft (65 N·m)
*213TC and 215TC Adapter Flange use 30 lbs ft (40 N m)

NOTE: Discharge loop must be high enough to keep liquid in the bottom stages during shut-down.

TORQUE VALUES

Pump Size

Tie Rod Nuts

Vent and Drain

1-5SV

22 lbs ft (30 N·m)

15 lbs ft (20 N·m)

10-22SV

37 lbs ft (50 N·m)

15 lbs ft (20 N·m)

33-125SV

44 lbs ft (60 N·m)

29 lbs ft (40 N·m)

VENT NEEDLE

Pump Size

1-5SV
10-22SV

7 lbs ft (9.5 N·m)

33-125SV

DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE

ATTEMPTING ANY MAINTENANCE. FAILURE TO DO SO CAN

CAUSE SHOCK, BURNS OR DEATH.

SYMPTOM
MOTOR NOT RUNNING

See Probable Cause – 1 through 5

LITTLE OR NO LIQUID DELIVERED BY PUMP

See Probable Cause – 6 through 12

POWER CONSUMPTION TOO HIGH

See Probable Cause – 3, 12, 13, 15

EXCESSIVE NOISE AND VIBRATION

See Probable Cause – 3, 6 - 8, 10, 12, 13, 16

PROBABLE CAUSE
1. Motor thermal protector tripped.
2. Open circuit breaker or blown fuse.
3. Impellers binding.
4. Motor improperly wired.
5. Defective motor.
6. Pump is not primed, air or gases in liquid.
7. Discharge, suction plugged or valve closed.
8. Incorrect rotation (three phase only).
9. Low voltage or phase loss.
10. Impellers worn or plugged.
11. System head too high.
12. NPSH

A

too low – excessive suction lift or losses.

13. Discharge head too low – excessive flow rate.
14. Fluid viscosity, specific gravity too high.
15. Worn bearing.
16. Pump, motor or piping loose.

Advertising