15

Figure 5

To remove the motor follow steps 1 through 4, as

provided in the “MECHANICAL SEAL REPLACE-

MENT” section of this manual.
For motor frames 213TC and larger, remove the 4 mo-

tor hex cap screws and the motor adapter.
Install the motor adapter flange onto the new motor,

torquing the 4 hex cap screws to the values provided in

the “ENGINEERING DATA” section of this manual.

Complete the reassembly following steps 17 through

22 in the “MECHANICAL SEAL REPLACEMENT”

section of this manual.
All additional unit service or maintenance, not ad-

dressed in this manual, should be performed at a

qualified service location. Contact your local dealer or

Goulds Water Technology distributor for assistance.