Spd pl us, Centrifugal p ump c ontr oller quick s tar t guide – Xylem IM244R04 SPD Plus Variable Speed Pump Control User Manual

Page 2

Advertising
background image

2

SPD PL

US

C

entrifugal P

ump C

ontr

oller

Quick S

tar

t Guide

Overview

The installa

tion of

the SPD PL

US adjust-able

speed drive follows the outline below

.

Task

PREP

ARE

for installa

tion

UNP

A

CK

the drive

PREP

ARE

mounting loca

tion

REMO

VE

the fr

ont cover

MOUNT

the drive

INS

TALL

wiring

CHECK

installa

tion

REINS

TALL

the cover

APPL

Y

power

ST

AR

T-UP

Assistant

Applica

tion

This guide pr

ovides a quick r

efer

ence for

installing SPD PL

US drives having a standar

d

enclosur

e (NEMA

1).

NO

TE:

T

his guide does not pr

ovide detailed

installa

tion,

safety or oper

ational instruc

-

tions.

See the Installa

tion Oper

ation Manual

for complete informa

tion.

Pr

epar

e for Installa

tion

W

ARNING!

T

he

Aquavar should ONL

Y

be installed by a qualified electrician.

Check

• Motor C

ompa

tibility – Motor type,

nominal curr

ent,

frequency and voltage r

ange must ma

tch drive

specifica

tions (3 phase motor only).

• Suitable Envir

onment – Drive r

equir

es he

ated,

indoor contr

olled envir

onment tha

t is suitable for

the selected enclosur

e below 122º F (50º C).

• Wiring – F

ollow local codes for wiring and fusing

requir

ements.

R

efer to NEC,

Local,

S

ta

te or Munici

-

pal codes.

Refer to the Installa

tion Oper

ation Manual and

confirm tha

t all pr

epar

ations ar

e complete.

Tools R

equir

ed

Scr

ewdrivers,

wir

e stripper

, tape me

asur

e,

mount

-

ing scr

ews or bolts,

and drill.

Use the following char

t to interpr

et the type code

found on the drive label.

C

ollect Motor Da

ta

C

ollect the following da

ta fr

om the motor namepla

te

pla

te for la

ter use in the

Aquavar star

tup:

Voltage

______________________________

• Nominal Motor Curr

ent

_______________

• Nominal F

requency

___________________

• Nominal Speed

______________________

• Nominal P

ower

_______________________

Unpack the Drive

NO

TE:

Lif

t the SPD PL

US by its chassis and

not

by its cover

.

1.

Unpack the drive.

2.

Check for any damage and notify the

shipper immedia

tely if

damaged com

-

ponents ar

e found.

3.

Check the contents against the or

der

and the shipping label to verify tha

t all

par

ts have been r

eceived.

Pr

epar

e the Mounting L

oca

tion

The drive r

equir

es a smooth,

ver

tical,

solid surface,

fr

ee fr

om

he

at and moistur

e,

with fr

ee

space for air flow – 200 mm (8

in.) above and below

, and 25

mm (1 in.) ar

ound the sides of

the drive.

1.

Mark the mounting

points.

2.

Drill the mounting holes.

R

emove the F

ront C

over

1.

R

emove the contr

ol panel

(display),

if

a

ttached.

2.

L

oosen the

captive scr

ew

at

the top

.

3.

P

ull ne

ar the

top to r

emove

the cover

.

Mount

the Drive

1.

P

osition the

SPD PL

US and use

scr

ews or bolts to

secur

ely tighten all

four corners.

2.

At

tach a warning

stick

er in the

appr

opria

te lan

-

guage on the inside

plastic shell.

Install

the Wiring

(copper only)

1.

Install thin-wall conduit clamps (not supplied) in the conduit/gland bo

x.

2.

Install conduit/gland bo

x.

Wiring P

ower

1.

C

onnect conduit runs to bo

x.

2.

R

oute input power and motor

wiring thr

ough conduits.

1

X0002

SPD

4

0600

N1

Single P

ump Drive

V

oltage

2 – 230

Volt

4 – 460

Volt

5 – 575

Volt

Nominal Horsepower

0400 = 40 HP

0500 = 50 HP

0600 = 60 HP

0750 = 75 HP

1000 = 100 HP

Enclosur

e and F

ilter Options

Blank = NEMA

3R,

no filter

N1 = NEMA

1,

no filter

F = NEMA

3R,

with filter

NO

TE:

HP r

ating is for r

efer

ence only

, and is based on 3Ø input power

.

3.

S

trip wir

es.

4.

C

onnect power

, motor and

gr

ound wir

es to the drive terminals.

See “P

ower Supply and

Wiring”

in the instruction manual.

Fr

ame Sizes R1…R4

* Single phase input power must use U1,

W1

and PE for wiring.

W

ARNING!

F

or floa

ting network

s

remove scr

ews a

t EM1 and EM3 on

Fr

ame Sizes R1…R4.

Fr

ame Size R5

Fr

ame Size R6

W

ARNING!

For floa

ting net

-

work

s r

emove

scr

ews a

t

F1 and F2

on F

rame

Sizes R5 or R6.