Wiring the t ransducer, Check installa tion, Reinstall the c over – Xylem IM244R04 SPD Plus Variable Speed Pump Control User Manual

Page 3: Apply p ower, Star t-up

Advertising
background image

3

Wiring

the T

ransducer

1.

R

oute the

tr

ansducer

cable

thr

ough

the conduit.

2.

S

trip the

tr

ansducer

cable

she

athing

and twist

the scr

een

wir

e.

3.

C

onnect the scr

een

wir

e of

the

tr

ansducer to

terminal X1-1.

4.

C

onnect the power supply wir

e of

the

tr

ansducer (r

ed or br

own) to terminal

X1-10.

5.

C

onnect analog output wir

e fr

om the

tr

ansducer (white or black) to

X1-5.

See

char

t in ne

xt column.

6.

Install the conduit/gland bo

x cover (1

scr

ew).

1

Digital input impedance 1.5 k

Ω

. Maximum voltage

for digital inputs is 30

V.

Check Installa

tion

Befor

e applying power

, perform the follow

-

ing check

s.

Check

Envir

onment conforms to specifica

tions.

The drive is mounted secur

ely

.

Pr

oper cooling space ar

ound the drive.

Motor and driven equipment ar

e r

eady for star

t.

Floa

ting network

s: Internal RFI filter disconnected.

Drive is pr

operly gr

ounded,

with pump/motor

.

Input power (mains) voltage ma

tches the drive

nominal input voltage.

The input power (mains) terminals,

U1,

V1,

W1,

ar

e connected and tightened as specified.

The input power (mains) fuses / mains switch installed.

The motor terminals,

U2,

V2,

W2,

ar

e connected

and tightened as specified.

Motor cable is r

outed away fr

om other cables.

NO power factor compensa

tion capacitors ar

e

connected to the motor cable.

Contr

ol terminals ar

e wir

ed and tightened as specified.

NO tools or for

eign objects (such as drill shavings) ar

e

inside the drive.

NO alterna

te power sour

ce for the motor is connected

– no input voltage is applied to the output of

the drive.

5

3

1

DIR

MENU

REM

11.1%

LO

C

REM

40.2 PSI

sp

0.0 PSI

ac

0.0 HZ

R

einstall the C

over

1.

Align the cover

and slide

it on.

2.

T

ighten

the captive

scr

ew

.

3.

R

einstall the

contr

ol panel.

Apply P

ower

Always r

einstall the fr

ont cover befor

e turn

-

ing power on.

W

ARNING!

T

he SPD PL

US will star

t

up automa

tically a

t power up

, if

the

external run command is on.

1.

Apply input power

.

When power is applied to the SPD PL

US,

the gr

een LED comes on.

NO

TE!

Befor

e incr

easing motor speed,

check tha

t the motor is running in the

desir

ed dir

ection.

Star

t-Up

Run the S

tar

t-Up

Assistant

to configur

e the motor and

system par

ameters.

If

this is

the first time the drive has been power

ed,

the display

will pr

ompt the user if

they

would lik

e to run the S

tar

t-

Up

Assistant.

Select

Yes to

run the S

tar

t-Up

Assistant.

If this is not the first time the drive has been power

ed,

follow the steps below:

1.

F

rom the Main Scr

een pr

ess MENU to

enter the MENU scr

een.

2.

Select QUICKS

TAR

T

3.

Select S

tar

t-Up

4.

F

ollow the menu pr

ompts to configur

e

the drive.

NO

TE!

F

or common par

ameters and

menu items,

use the Help K

ey to

display descriptions.

If

you encounter

Alarms or F

aults,

use the Help K

ey or

refer to the Diagnostic section of

the

instruction manual.

Advertising