APPENDIX B: FUSE AND WIRE SIZING

(CONTINUED)

SPD PLUS OUTPUT WIRE SIZING CHARTS

Maximum Allowable Conductor Length (50˚C Ambient, 5% drop)

Controller

Ratings

Conductor Size for 75˚C Rated Wire

(Lengths in Bold Require 90˚C Rated Wire)

Controller

Output

Motor

HP

Motor

FLA

6

4

3

2

1

1/0

2/0

3/0

4/0

250

300

350

400 500 600 750 1000

230V

20

54

408

522

667

846

1075

1364

1726

2181

2580

3100

3627

25

68

404

519

662

843

1074

1362

1723

2041

2454

2873

3289

30

82

420

539

689

881

1120

1420

1684

2026

2374

2720

3392

40

96

450

579

743

947

1204

1430

1722

2019

2316

2890 3484

50

116

603

771

984

1172

1413

1659

1906

2382 2871 3610

60

130

679

869

1038

1253

1472

1693

2118 2553 3214

460V

40

53

834

1066 1360

1726

2191

2780

3519

50

70

782 1005 1283

1635

2083

2643

3346

3963

60

80

865 1108 1416

1809

2298

2914

3455

75

96

901 1158 1487

1894

2408

2861

3444

100

127

1087 1393 1783 2128 2568

3018

3469

575V

40

43

802

1315

1671

2124 2689 3407

50

54

1017 1301 1661

2108

2676

3396

60

64

1076 1379 1756 2234

2842

3602

75

76

1146 1466 1871

2388

3032

3842

100

101

1366 1758

2242

2853

3391

APPENDIX C: WEIGHTS AND DIMENSIONS

CONTROLLER DIMENSIONS

NEMA 1 Enclosures

NOTE
Controllers with an N1 suffix have a NEMA 1
enclosure and are rated for indoor use only.

NEMA 1 Enclosure Dimensions

Ref.

R4

R5

R6

mm

in

mm

in

mm

in

W

203

8.0

265

10.4

300

11.8

H

596

23.4

602

23.7

700

27.6

H2

583

23.0

578

22.8

698

27.5

H3

689

27.1

739

29.1

880

34.6

D

262

10.3

286

11.3

400

15.8