8.

Maintenance/Disassembly

Pumps are subject to wear. If the pump is blocked (see section 9) or
grinding noises are audible, check the pump and replace it if necessary.
Procedure:

- Disconnect the pump from the mains.
- Shut off supply and drain lines. If there are no shut-off

devices, drain the system so that the fluid level is
beneath that of the pump.

- Loosen the union nut by hand or with an appropriate

tool (such as a strap wrench) and carefully pull the
motor out of the pump housing.

Residual water may leak out of the rotor cavity. Prevent
the pump's electrical connection from getting wet.

For figure 5:
- Carefully but firmly pull the rotor / impeller upward by hand and remove

it.

- If necessary, remove foreign bodies and impurities/deposits with

appropriate agents. Reinsert the rotor / impeller.

- The bearing is worn if the rotor / impeller cannot be freely moved or if

wear marks are visible. In this case, replace the rotor, the pump motor,
or the entire pump.

9.

Operating signal light / Troubleshooting / Warranty

Work on electrical parts may only be performed by

authorized electricians.


When the electrical connection to the pump is properly made and the
pump is powered, a white or blue light (depending on the actual operation
mode) is constantly lit in the knob of the Ecocirc pump.
Mode selection: turn the knob to the end position below 1 then turn it
back within 5 sec.
Constant Speed: white light; Proportional Pressure: blue light
Faults are indicated as follows:

Operating LEDs /

Blinking light

Cause

Solution

Off

• Pump is not connected

or is incorrectly

connected

• Power failure

• Check connection


• Check mains + circuit

breaker

ATTENTION