20

temperature rises above a safety limit, the pump will shut itself off. The
pump will automatically restart after cooling down.

10.

Disposal

This product and parts thereof must be disposed of in an environmentally
friendly manner. Applicable local regulations must be followed.

11.

Exploded View (see figure 6)

1. Supply cable
2. Stator/pump motor
3. Union nut
4. O-ring
5. Impeller / Rotor
6. Pump housing
7. Connection thread
8. Continuously adjustable selector knob with built-in LED

12.

EC DECLARATION OF CONFORMITY « ORIGINAL »

LOWARA SRL UNIPERSONALE, WITH HEADQUARTERS IN VIA
VITTORIO LOMBARDI 14 - 36075 MONTECCHIO MAGGIORE VI -
ITALIA, HEREBY DECLARES THAT THE PRODUCT

CIRCULATOR (SEE LABEL ON FIRST PAGE)


FULFILLS THE RELEVANT PROVISIONS OF THE FOLLOWING
EUROPEAN DIRECTIVES
• MACHINERY 2006/42/EC (ANNEX II: THE TECHNICAL FILE IS

AVAILABLE FROM XYLEM WATER SYSTEMS HUNGARY KFT,
KÜLSŐ-KÁTAI ÚT 41, 2700 CEGLÉD, MAGYARORSZÁG).

• ELECTROMAGNETIC COMPATIBILITY 2004/108/EC
AND THE FOLLOWING TECHNICAL STANDARDS
• EN 60335-1, EN 60335-2-51
• EN 55014-1:2006+A1:2009, EN 55014-2:1997+A1:2001+A2:2008

MONTECCHIO MAGGIORE, 31.07.2012
AMEDEO VALENTE
(DIRECTOR OF ENGINEERING AND R&D)