MIQ/Blue PS

Installation

3 - 3

ba76095e02

01/2013

With an MIQ/PS power supply module (18 W), there is still an
energy reserve of 10.2 W for any future extensions.

3.2.3

Topology and terminator switch

For failure-free operation, the terminator switches (terminating resis-
tors) must always be set to ON on two MIQ modules of the
IQ S

ENSOR

N

ET

island. On which modules this is required results from

the topology of the IQ S

ENSOR

N

ET

island:

Fig. 3-1

Correct setting of the terminator switches

Main line (trunk
line)

Longest cable section with terminator switches at
its ends.
The terminator switches must be set to On at both
ends.
If all MIQ modules are located at one point, i. e. in
a module stack, the length of the main line is zero
(star-shaped wiring).

Branch line

All lines branching from the main line.
Branch lines can be branched further.

X6

X5

X4

SENSORNET 2

RED

SHIELD

GREEN

X3

X2

X1

SENSORNET 1

RED

SHIELD

GREEN

ON

OFF

SN

TERMINA

TO
R

SN Terminator