5 electrical connections: general instructions, Electrical connections: general instructions -14 – YSI MIQ/Blue PS Set User Manual

Page 24

Advertising
background image

Installation

MIQ/Blue PS

3 - 14

ba76095e02

01/2013

3.5

Electrical connections: General instructions

Cable glands

All electric cables are fed into the enclosure of the MIQ/Blue PS from
below through prepared openings. Cable glands with different clamping
ranges are provided with the MIQ/Blue PS to provide sealing between
the cable and enclosure as well as for strain relief. Select the suitable
cable gland for the respective cable diameter:

Small, clamping range 4.5 to 10 mm. This cable gland is suitable for

all IQ S

ENSOR

N

ET

cables.

Large, clamping range 7 to 13 mm. This cable gland is required for

cable sheaths with an outer diameter of more than 10 mm and is
screwed into the enclosure via an extension piece.

Note
If necessary, you can order additional large cable glands as a set of 4
pieces (model EW/1, order number 480 051).

Sealing ring 20 x 15 x 1 mm

Cable gland M16

Blind plug

Sealing ring 20 x 15 x 1 mm

Extension piece M16/M20

Sealing ring 24 x 19 x 2 mm

Cable gland M20

Advertising