Xylem HYDROVAR WATERCOOLED User Manual

Page 12

Advertising
background image

12

en

Contents

1

Important safety instructions..................................................................................................................... 12

2

Technical Data............................................................................................................................................ 13

3

Mounting and accessories......................................................................................................................... 14

4

Electrical connection, control terminals and Display unit........................................................................ 17

5

Status signal and required value adjustment ........................................................................................... 18

6

Error Messages .......................................................................................................................................... 19

7

Other failures and possible causes........................................................................................................... 20

8

Maintenance and Notes.............................................................................................................................. 20

Follow the Pump Operating and Maintenance Instructions

1

Important safety instructions

Read and follow the operating instructions and safety

instructions carefully before starting operation! All modifications

must be done by qualified technicians!

In addition to the instructions contained in this service manual please pay attention to universal safety and

accident preventing regulations!

Warns that failure to observe the precaution may cause electric shock.

Warns that failure to observe the precaution may cause personal injury or damage to property.


The Hydrovar-Watercooled must be disconnected from the power supply before any work can be carried out in the
electrical or mechanical part of the system.

Installation, maintenance and repair work may only be carried out by trained, skilled and qualified personnel.

Unauthorized modifications or changes to the system make all guarantees null and void.

When in operation, the motor can be stopped by remote control, whereby the Hydrovar-Watercooled and the
motor remain under voltage. For safety reasons, the unit has to be disconnected from the power supply when

carrying out work on the machinery as locking out the equipment by switching off the release mechanism or set

value cannot prevent accidental starting of the motor.

When the Hydrovar-Watercooled is connected to power supply, the components of the power unit
as well as certain components of the master control unit are also connected to the power supply.

Touching these components seriously endangers life!

Before removing the Hydrovar-Watercooled cover the system must be disconnected from the power supply. After

switching off the power supply wait at least 5 minutes before starting work on or in the Hydrovar-Watercooled
(the capacitors in the intermediate circuit are discharged by the installed discharge resistors first).

Notice: Furthermore, care must be taken not to short circuit the neighboring components when connecting the

external control wires.

Isolate open cable ends which are not in use.