5 Fault finding

Referring to

Figure 10

(in case of plug-connected

models) and to

Figure 11

(in case of terminal-

connected models), as briefly described in par. 4.1

In case of any alarm that allows the pump
to continue running, the display shows
alternatively alarm code (see par. 5.1) and
last quantity selected, while the status
indicator becomes orange

In case of a failure that stops the pumps,
the display shows the error code (see par.
5.2) permanently and the status indicator
becomes red

5.1 Alarm codes

Alarm
code

Description

Cause

A01

Water probe alarm

Fluid sensor
anomaly

A02

Water over-temperature
alarm

High temperature
on the fluid

A05

Data memory alarm

Data memory
corrupted

A06

External water temp.
probe alarm

External
temperature probe
anomaly

A07

Pressure sensor alarm

External pressure
sensor anomaly

A12

Twin pump
communication alarm

Twin pump
communication
lost

A20

Internal alarm

5.2 Error codes

Error
code

Description

Cause

E01

Internal communication
error

Internal
communication
lost

E02

Motor overload error

High motor current

E03

DC-bus overvoltage error

DC-bus
overvoltage

E04

Trip control error

Motor stall

E05

EEPROM Data memory
error

EEPROM Data
memory corrupted

E06

Grid voltage error

Voltage supply out
of operating range

E07

Motor winding
temperature error

Motor thermal
protection trip

E08

Power module
temperature error

Inverter thermal
protection trip

E09

Generic Hardware error

Hardware error

E10

Dry-run error

Dry run detection