Installation, Operating and Maintenance Instruction

Model LR, LMR, LRZ, LMZ


page 46

 Set the pump unit on the base and adjust the

nozzles. Anchor bolts must be cast with the
foundation.

 If vibrations are transmitted to the foundation from

adjoining components, it must be guarded through
adequate vibration damping padding (vibrations
from outside can impair the bearing).

 To prevent vibrations being transmitted to

adjoining components, the foundation should be
laid on a suitable insulating base.

The size of these insulating pads will vary,
depending on circumstances, and should
therefore be determined by an experienced
specialist.

5.2 Connection of Piping to the Pump

The pump must not be used as fixed point for
the piping. The permitted piping loads must not
be exceeded, refer to chapter 3.7.

5.2.1 Suction and discharge pipe
 The pipes must be of a size and design that liquid

can flow freely into the pump and that the pump
functions without problems. Particular attention is
to be paid to ensuring that suction pipes are
airtight and that the NPSH values are observed.
Under suction lift condition the suction pipe lays in
the horizontal section towards the pump so that it
is slightly inclined upwards so that no air traps
occur. Do not install fittings or elbows right before
the suction nozzle.

 Piping for direct installation of LR-, LMR-, LRZ- or

LMZ-pumps must show adequate firmness. Keep
in mind vibration insulation (see chapter 5.1).

 When laying the pipes, make sure that the pump

is accessible for maintenance, installation and
disassembly.

 Notice "Permitted Forces on Flanges" (chapter

3.7).

 Before connecting up to pump: remove protective

coverings from suction and discharge branches.

 Before starting up, the pipe system, fittings and

equipment must be cleaned to remove weld
spatter, scale etc. Any pollutants are to be
completely removed from pump units that are
directly or indirectly connected to drinking water
systems before being installed and taken into use.

 To protect the shaft sealing (especially mechanical

seals) against foreign impurities, it is
recommended that a sieve, 800 micron, is
installed in the suction / intake pipe when the
motor is being started up.

 If the pipe system is tested with the pump

installed, do not exceed the maximum permitted
casing pressure of the pump and/or shaft sealing
(see data sheet).

 When emptying the pipe after the pressure test,

make sure that the pump is treated properly
(danger of rust and problems when starting up).

5.2.2 Additional connections LR, LRZ
The following additional connections are available:

Connection

Description

Dimension

E Pump

drain

R3/8"

L Air

release

R1/8"

M Pressure

gauge

R3/8"

5.2.3 Additional connections LMR, LMZ
The following additional connections are available:

Connection

Description

Dimension

E Pump

drain

R3/8"

L Air

release

R1/4"

M Pressure

gauge

R1/4"


5.3 Drive

The motor design of the pump is shown in the order
confirmation or on the motor name plate.
Note the Operating Instructions of the motor
manufacturer.

If in the process of repair a new motor is used, the
following has to be noticed:
 The motor must comply with the requirements

stated in sheet 1130.1A608 (order from
manufacturer, on demand).

 Clean motor end and motor flange of new motor

carefully (remove varnish).

5.4 Electric Connection

Electrical connection work may only be carried
out by an authorised professional. The rules
and regulations valid for electrical technology,
especially those concerned with safety
measures, must be observed. The regulations
of the national power supply companies
operating in that area must also be observed.

Before starting work, check that the information on the
motor name plate is the same as the local mains
network. The power supply cable of the coupled drive
motor must be connected up in accordance with the
wiring diagram produced by the motor manufacturer.
A protective motor switch must be provided.

The direction of rotation must only be checked
when the pump is full. Dry running will cause
damage to the pump.