D

ischarge too l

o

w

D

ischarge stops after a ti

me

H

ead too l

o

w

H

ead too hi

gh

D

ri

v

e mechani

sm overl

oaded

P

u

mp not runni

ng qui

etl

y

Temperature i

n

pump too hi

gh

Temperature i

n

shaft seal

ing too hi

gh

Temperature at the beari

ng too hi

gh

P

u

mp l

eaki

ng

Leakage rate at shaft seal

ing too hi

gh

Cause

Solution

■ Back-pressure

too

high

check facility for pollution, open discharge valve
reduce resistance in discharge pipe (e.g. clean filter if
necessary)
use larger impeller (note available motor power)

Back-pressure too low, discharge too low

throttle discharge valve

■ ■ Speed

too

high

reduce

speed

compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value setting

■ Speed

too

low

increase speed (check available motor power)
compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value settings

■ ■

■ ■

Flow too little

increase min. flow (open discharge valve, bypass)

Flow too big

reduce flow (throttle discharge valve)

■ ■

Impeller diameter too big

use smaller impeller

Impeller diameter too small

use larger impeller (check available motor power)

■ ■

Pump and/or pipes not completely filled with liquid

fill
vent

■ ■ ■ Pump

or

suction/intake

pipe

blocked

clean

■ Air

pocket

in

pipeline

vent
improve course of pipe

■ ■ ■

■ ■

Suction height too big / NPSH of system too small

increase liquid level and admission pressure
reduce resistance in the intake/suction pipe (change course
and rated width, open shut-off valves, clean filters)

■ ■ ■ Air

being

sucked

in

increase

liquid

level

check if suction pipe is vacuum-tight

■ ■ ■

Air being sucked in through shaft sealing

clean sealing pipe
increase sealing pressure
replace shaft sealing

Direction of rotation is wrong

swap over two phases of power supply (to be done by an
electrician)

Inner components suffering from wear

replace worn parts

Density and/or viscosity of liquid handled is too high

seek assistance

■ Lines and roughness at shaft

replace parts

■ Deposits on mechanical seal

clean
replace mechanical seal if necessary
if necessary provide additional rinsing or quench

■ Impeller out of balance

remove blocks/deposits
replace impeller if broken or unevenly worn
check shafts to ensure that they are running true

■ ■

■ ■ ■ Forces in pipeline too high (pump unit under strain)

change (support pipes, use compensators, etc.)
is foundation plate/frame properly cast in place?

■ Electricity

supply

not

right

(2-phase running)

check voltage of all phases
check cable connections and fuses

Sealing insufficient

tighten screws
replace sealing

■ Bearing

damaged

replace

Relief fittings insufficient

clean relief openings in impeller
replace worn parts (impeller, split rings)
adjust in line with the system pressure/intake pressure given on
ordering

■ System-related

vibrations

(resonance)

seek

assistance