Model lr, lmr, lrz, lmz, Page 51 – Xylem LMZ User Manual

Page 55

Advertising
background image

Installation, Operating and Maintenance Instruction

Model LR, LMR, LRZ, LMZ


page 51

D

ischarge too l

o

w

D

ischarge stops after a ti

me

H

ead too l

o

w

H

ead too hi

gh

D

ri

v

e mechani

sm overl

oaded

P

u

mp not runni

ng qui

etl

y

Temperature i

n

pump too hi

gh

Temperature i

n

shaft seal

ing too hi

gh

Temperature at the beari

ng too hi

gh

P

u

mp l

eaki

ng

Leakage rate at shaft seal

ing too hi

gh

Cause

Solution

■ Back-pressure

too

high

check facility for pollution, open discharge valve
reduce resistance in discharge pipe (e.g. clean filter if
necessary)
use larger impeller (note available motor power)

■

■

■

Back-pressure too low, discharge too low

throttle discharge valve

■ ■ Speed

too

high

reduce

speed

compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value setting

■

■ Speed

too

low

increase speed (check available motor power)
compare speed of motor with specified pump speed (rating
plate)
when adjusting speed (frequency transformer) check reference
value settings

■ ■

■ ■

Flow too little

increase min. flow (open discharge valve, bypass)

■

Flow too big

reduce flow (throttle discharge valve)

■ ■

Impeller diameter too big

use smaller impeller

■

■

Impeller diameter too small

use larger impeller (check available motor power)

■

■

■ ■

Pump and/or pipes not completely filled with liquid

fill
vent

■ ■ ■ Pump

or

suction/intake

pipe

blocked

clean

■

■ Air

pocket

in

pipeline

vent
improve course of pipe

■ ■ ■

■ ■

Suction height too big / NPSH of system too small

increase liquid level and admission pressure
reduce resistance in the intake/suction pipe (change course
and rated width, open shut-off valves, clean filters)

■ ■ ■ Air

being

sucked

in

increase

liquid

level

check if suction pipe is vacuum-tight

■ ■ ■

Air being sucked in through shaft sealing

clean sealing pipe
increase sealing pressure
replace shaft sealing

■

■

Direction of rotation is wrong

swap over two phases of power supply (to be done by an
electrician)

■

■

■

■

Inner components suffering from wear

replace worn parts

■

■

■

Density and/or viscosity of liquid handled is too high

seek assistance

■

■ Lines and roughness at shaft

replace parts

■

■ Deposits on mechanical seal

clean
replace mechanical seal if necessary
if necessary provide additional rinsing or quench

■

■ Impeller out of balance

remove blocks/deposits
replace impeller if broken or unevenly worn
check shafts to ensure that they are running true

■ ■

■ ■ ■ Forces in pipeline too high (pump unit under strain)

change (support pipes, use compensators, etc.)
is foundation plate/frame properly cast in place?

■ Electricity

supply

not

right

(2-phase running)

check voltage of all phases
check cable connections and fuses

■

Sealing insufficient

tighten screws
replace sealing

■

■ Bearing

damaged

replace

■

Relief fittings insufficient

clean relief openings in impeller
replace worn parts (impeller, split rings)
adjust in line with the system pressure/intake pressure given on
ordering

■ System-related

vibrations

(resonance)

seek

assistance


Advertising