Command and Response Table for Basic SIS Commands

Command

ASCII command

(host to device)

URL Encoded

(web)

Response

(device to host)

Information requests

Firmware Version

Q

*Q

X1!]

Firmware and build version

*Q

*Q

X1!]

Kernel firmware and build

**Q

**Q

X1!]

Verbose version info

0Q

0Q

Sum of 2Q-3Q-4Q

]

Firmware version

1Q

1Q

X1!]

Bootstrap Version

2Q

2Q

X1!]

Factory Firmware Version

3Q

3Q

X1!

plus web ver.-desc-UL

date/time

]

Updated firmware version

4Q

4Q

X1!

plus web ver.-desc-UL

date/time

]

NOTE: An asterisk (*) after the version number indicates the currently running version. Question marks (?.??) indicate that

only factory firmware is loaded. A caret (^) indicates the firmware version that should be running, but a Mode 1 reset
was executed and the default factory firmware is running. An exclamation point (!) indicates corrupted firmware.

Query part number

N

N

60–1054-01

]

Query model name

I

I

V00x00•A06x04

]

Query model name

1I

1I

DMP•64

]

Query model description

2I

2I

Digital•Matrix•Processor

]

Query system memory
usage

3I

3I

#Bytes used out of
#KBytes

]

Query user-memory usage

4I

4I

#Bytes used out of
#KBytes

]

NOTE:

X1!

= Version number

Firmware version number to second decimal place (x.xx)

Version and Build number adds four digits (x.xx.xxxx)

to the Version number

DMP 64 • SIS Programming and Control